HOT2000 - supplementary heating not being taken into account

Started this discussion. Last reply by Stephen Wierzbicki Feb 28. 4 Replies

Hi there, I am modelling a 3,000 sqft house which is designed as using two gas powered furnaces to heat the entire house. They are the same model of furnace, one has a capacity of 80,000 BTUh and the…Continue

Tags: furnace, heating, HOT2000

HOT2000 - model first floor garage?

Started Feb 2 0 Replies

Hi all, I am modelling a proposed new residence in HOT2000 to prove code compliance to our local jurisdiction. The building is three storeys with a slab-on-grade foundation, and the first storey is a…Continue

HOT2000 Modelling Addition

Started this discussion. Last reply by Jason Vandever Jan 31. 5 Replies

Hi all, I am a new energy modeler in Canada, and I am trying to figure out how to model an addition to an existing house. The addition will use the existing furnace. I was thinking I would only model…Continue

 

Kyla Marie's Page

Latest Activity

Stephen Wierzbicki replied to Kyla Marie's discussion HOT2000 - supplementary heating not being taken into account
"We do not find many 3,000 square foot homes that require 140,000 BTU's of heat but that is another subject. Could you use one 120,000 BTU fully modulating gas warm air furnace?"
Feb 28
Michael Cuomo replied to Kyla Marie's discussion HOT2000 - supplementary heating not being taken into account
"An undersized furnace will work fine for the majority of the time, but every once in a while it won't get the house quite as warm as desired. An over-sized furnace will also be less efficient. A furnace is least efficient when it first fires up…"
Feb 28
Franco Oyuela replied to Kyla Marie's discussion HOT2000 - supplementary heating not being taken into account
"Hire a professional to inspect the system. I agree with Daniel, Two furnaces would use more energy than one furnace. https://www.heatingair.org/"
Feb 26
Daniel Baur-McGuire replied to Kyla Marie's discussion HOT2000 - supplementary heating not being taken into account
"This screams oversized! Why the two furnaces? Split system for two floors? I would think 2 furnaces would use more energy than 1. As you have to start up and power two blowers now. Sorry not familiar with HOT2000. Good Luck! "
Feb 25
Kyla Marie posted a discussion

HOT2000 - supplementary heating not being taken into account

Hi there, I am modelling a 3,000 sqft house which is designed as using two gas powered furnaces to heat the entire house. They are the same model of furnace, one has a capacity of 80,000 BTUh and the other of 60,000 BTUh. I am modelling the 80,000 BTUh furnace in the Type 1 furnace tab of the heating/cooling section, and the other furnace as a supplementary heating source. My problem is that HOT2000 does not seem to be taking the supplementary heating source into account. I have an error…See More
Feb 25
Kyla Marie posted a discussion

HOT2000 - model first floor garage?

Hi all, I am modelling a proposed new residence in HOT2000 to prove code compliance to our local jurisdiction. The building is three storeys with a slab-on-grade foundation, and the first storey is a garage. The living spaces are on the second and third floors. My question is, how should I model this in HOT2000? The garage is heated and the garage walls are insulated, and the floor between the first and second storeys (above the garage) is insulated, obviously. Does anyone know if I can model…See More
Feb 2
Diane Chojnowski left a comment for Kyla Marie
"Hi Kyla, Welcome to Home Energy Pros Forum. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos, and upcoming events. If you're blogging about home performance, this is the place for…"
Feb 1
Jason Vandever replied to Kyla Marie's discussion HOT2000 Modelling Addition
"I agree. 99% of the time additions are best suited for the prescriptive method. No modeling needed."
Jan 31
Kyla Marie replied to Kyla Marie's discussion HOT2000 Modelling Addition
"Ah, I see. Thanks very much, Dave!"
Jan 29
David Baerg replied to Kyla Marie's discussion HOT2000 Modelling Addition
"No.  I think the person at NRCan didn't fully understand your situation.  One heating source means it's one house.  It's also important to distinguish between a duplex and a semi-detached.  Semi-detached houses…"
Jan 29
Kyla Marie replied to Kyla Marie's discussion HOT2000 Modelling Addition
"Hi Dave, thank you for your reply! The purpose of the model is to show code compliance for the addition. I am doing it from plans, but I don't have plans for the entire house, or assemblies for the existing walls. I ended up speaking to someone…"
Jan 29
Shawn Powell left a comment for Kyla Marie
"Hi Kyla, Yes, Dave is right.. you need to model the whole house. Model the existing wall perimeters, up until where the hypothetical addition walls start, and then model those separately. You would ignore any old walls that would essentially become…"
Jan 28
David Baerg replied to Kyla Marie's discussion HOT2000 Modelling Addition
"Hi Kyla, In HOT2000, you need to model the whole house.  Are you doing this from plans?  What's the purpose of modelling this? Dave Baerg"
Jan 28
Kyla Marie posted a discussion

HOT2000 Modelling Addition

Hi all, I am a new energy modeler in Canada, and I am trying to figure out how to model an addition to an existing house. The addition will use the existing furnace. I was thinking I would only model the addition, but in the "Natural Air Infiltration" tab, I would enter in the volume for the entire house, and make sure that the output capacities for the existing HRV reflect the addition. Any thoughts? Has anyone modeled an addition in HOT2000 before? Thanks!See More
Jan 28

Profile Information

Company
KRN Design
Role in Home Performance Marketplace
Architect / designer, Building energy modeler

Comment Wall (2 comments)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 9:47am on February 1, 2019, Diane Chojnowski said…

Hi Kyla,

Welcome to Home Energy Pros Forum. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos, and upcoming events. If you're blogging about home performance, this is the place for you!

Thanks!

Diane, HEP Forum Moderator

At 6:54pm on January 28, 2019, Shawn Powell said…

Hi Kyla,

Yes, Dave is right.. you need to model the whole house. Model the existing wall perimeters, up until where the hypothetical addition walls start, and then model those separately. You would ignore any old walls that would essentially become inside space after the addition is completed (except for any shared foundation walls). Note that depending on the size of the addition, the output capacity of the heating system might need to be increased so you don't get an error message.

 
 
 

Forum Discussions

Exterior green cladding

Started by Luis Hernandez in General Forum. Last reply by Dennis Heidner 11 hours ago. 1 Reply

Mini-Crawl Spaces between City Row-Home's Conditioned Stories

Started by Robert Logston in General Forum. Last reply by Daniel Baur-McGuire 14 hours ago. 6 Replies

Faces & Places of HPC19

Started by Diane Chojnowski in General Forum Apr 5. 0 Replies

high rise humidity

Started by Steve Nations in HVAC. Last reply by Dennis Heidner Apr 3. 7 Replies

Follow the action at #HPC19

Started by Diane Chojnowski in General Forum Apr 2. 0 Replies

Unvented Roof Assembly

Started by Patrick Michaelyan in General Forum. Last reply by Wallacebastien Mar 30. 6 Replies

Technology and Customer Service

Started by Kelly Caplenas in General Forum. Last reply by Franco Oyuela Mar 25. 1 Reply

Latest Activity

Dennis Heidner replied to Luis Hernandez's discussion Exterior green cladding
"Why do you feel the planks are too old?  Are they falling off themselves?  Cedar siding…"
11 hours ago
Al Tibbs shared Don Fugler's discussion on Facebook
12 hours ago
Daniel Baur-McGuire replied to Robert Logston's discussion Mini-Crawl Spaces between City Row-Home's Conditioned Stories
"This sounds like a job for AeroBarrier and AeroSealing. Both products will seal the issues from the…"
14 hours ago
Daniel Baur-McGuire commented on Joe Hughes's blog post Christine Oliver, M.D. – Odors, Multiple Chemical Sensitivities and More an MD’s Perspective
"One of the best building science podcasts! I have learned so much from listendign to this…"
15 hours ago
Anna Stern is now a member of Home Energy Pros Forum
16 hours ago
Pearl Certification posted blog posts
17 hours ago
tedkidd commented on Diane Chojnowski's blog post How to spur home energy upgrades? Persuasive assessment reports
"I was a respondent. The reports I saw seemed tailored to the things utility programs care about…"
17 hours ago
tedkidd liked Diane Chojnowski's blog post How to spur home energy upgrades? Persuasive assessment reports
17 hours ago

© 2019   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service