Dav Camras
  • Male
  • West Hills, CA
  • United States
Share on Facebook Share
  • Blogs
  • Discussions (9)
  • Events
  • Groups
  • Photos
  • Photo Albums
  • Videos

Dav Camras's Discussions

Adding blown insulation to poorly installed batts?

Started this discussion. Last reply by Peter Krych Aug 17, 2018. 10 Replies

I am curious about other's experience as I get asked the following question all the time: Is it necessary to pull out a poorly installed batt of insulation or will a subsequent blow of cellulose or…Continue

Tags: retrofit, insulation

E.L.M. Aquastar by E.L.M Leblanc SA france

Started Jul 2, 2018 0 Replies

I was hired to rate a house and found an ELM Aguastar 125 VP/VPS installed in the house. It is a tankless 125k Btu natural gas hot water heater with a continuously burning pilot light. Anyone know…Continue

Tags: heating, water, Hot

Experience with new energy monitoring tools such as Curb, Sense, Nerio and Smapee

Started this discussion. Last reply by Dav Camras Oct 8, 2018. 25 Replies

I have been trying to get feedback from people's experience with these breaker box monitoring tools. Do any of them work and provide useful data. I frequently get called by people who want me to…Continue

Tags: monitoring, energy, house, whole

Low Leakage home with cathedral ceiling

Started this discussion. Last reply by Rob Buchanan Dec 21, 2017. 5 Replies

I am curious/concerned about advising a tight house (addition) with a cathedral ceiling. I understand that normally, one should keep a 1-2" gap in the rafter bay above the insulation as an air gap.…Continue

Tags: control, moisture, enclosure, Tight

 

Dav Camras's Page

Latest Activity

Dav Camras replied to Dav Camras's discussion Experience with new energy monitoring tools such as Curb, Sense, Nerio and Smapee
"Have you used it? Does anyone install a circuit level monitoring devise for a month or two and then take it out once you have a month's worth of data? Seems they are pretty expensive to devote to each client and once you have the general idea…"
Oct 8, 2018
John White replied to Dav Camras's discussion Experience with new energy monitoring tools such as Curb, Sense, Nerio and Smapee
"It is a whole house monitor device. It is similar to the TED Energy Detective device. Thanks, for sharing knowledge on these breaker box monitoring tools. These devices are really useful for homeowners using HVAC systems."
Oct 8, 2018
Peter Krych replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"I agree, it is wasteful to remove and dump old insulation. I still does its job. Air sealing is important so after that's done blow cellulose and a good job will be had for a much lower price."
Aug 17, 2018
Sam Feder liked Dav Camras's discussion Adding blown insulation to poorly installed batts?
Aug 16, 2018
Brian Robinson replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"YES, YES, & YES!!! Bat droppings, mouse droppings, dead mice, nuts, seeds, acorns, lack of access to properly air seal, these are a few of my least favorite things . . . "A 1994 report by the International Agency for Research on Cancer…"
Aug 15, 2018
Don Hynek replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"It's far more sustainable to re-use existing product, if there's no hazard. (It's also cheaper! And easier!) You want to assure that the attic is air-sealed anyway, so when you put them back you have a cheap opportunity to undo the…"
Aug 6, 2018
Don Hynek replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"It's far more sustainable to re-use existing product if there's no hazard. (It's also cheaper! And easier!) You want to assure that the attic is air-sealed anyway, so when you put them back you have a cheap opportunity to undo the…"
Aug 6, 2018
Matt Sharpe replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"I have seen this done well too and may be the best cost effective approach considering the insulation is in good condition. It does have value if installed like it was meant to be. Air tightness is the indicator of success. If you are good with…"
Aug 3, 2018
Ed Minch replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"After lifting specific batts for blower-door/IR/experience guided air sealing, (rarely with 2 part foam) my crews will use a narrow rake to push batts down against the ceiling and around wiring and framing anomalies.  Then we will blow on top.…"
Aug 2, 2018
tedkidd replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"What Matt said. Remove everything. Air seal. Ideally with 2 part foam. Blower door test to find remaining leaks. Install fresh. The insulation has little value without air sealing. More of worthless is still worthless. We are removing…"
Aug 2, 2018
Dav Camras replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"The "sad" part is the attic insulation is new and clean. The house was remodeled a few years ago and they want AC b/c it is so hot. Poor batt insulation quality with big skylight shafts have to be part of the problem. "
Aug 2, 2018
Matt Sharpe replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"Best practice would be to remove the old poorly installed stuff to gain access for comprehensive air sealing, eave vent baffle installation, chimney air seal and insulation dams, etc. and then re-insulate with blown in. If best practice is not your…"
Aug 2, 2018
David Butler replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"When topping off an existing ceiling with batts, there's a cost to pulling out the old. True, the blown-in may not fill in all the gaps, but you'd likely get more benefit by spending that money on additional blown-in on top. A more worthy…"
Aug 2, 2018
Dav Camras posted a discussion

Adding blown insulation to poorly installed batts?

I am curious about other's experience as I get asked the following question all the time: Is it necessary to pull out a poorly installed batt of insulation or will a subsequent blow of cellulose or fiberglass fill in most of the missing gaps? What are people's experiences?Thanks. See More
Aug 2, 2018
Dav Camras posted a discussion

E.L.M. Aquastar by E.L.M Leblanc SA france

I was hired to rate a house and found an ELM Aguastar 125 VP/VPS installed in the house. It is a tankless 125k Btu natural gas hot water heater with a continuously burning pilot light. Anyone know its energy efficiency rating (at least when new)?Thanks. See More
Jul 2, 2018
Tom Roth replied to Dav Camras's discussion Experience with new energy monitoring tools such as Curb, Sense, Nerio and Smapee
"Not exactly for amature's or hobbyists. It may be more accurate because it's monitoring each circuit independently, but much more work and really should be installed by an electrician. This is probably a very good industrial solution."
May 16, 2018

Profile Information

Company
HouseSmart Green Solutions/HERSRaterLA
Role in Home Performance Marketplace
Building energy modeler, Energy auditor / assessor / analyst
Professional Certification
BPI, HERS Rater, RESNET
Website URL
http://housesmartgreensolutions.com

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 4:33pm on November 6, 2017, Diane Chojnowski said…

Hi Dav,

Welcome to Home Energy Pros Forum. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo.

Thanks!
Diane, HEP Moderator

 
 
 

Forum Discussions

REALLY????

Started by Danny Gough in HVAC. Last reply by Danny Gough 20 hours ago. 12 Replies

How to Insulate Exposed Outdoor Ductwork?? Help

Started by Daniel Baur-McGuire in General Forum. Last reply by Bradford E. White yesterday. 7 Replies

Where to spend my marketing dollars?

Started by Trip Smith in Marketing. Last reply by Building Performance Institute on Tuesday. 10 Replies

Easy Tests for HVAC during audit

Started by Craig Bird in Weatherization. Last reply by John White May 9. 19 Replies

Water heater ventilation question

Started by Luis Hernandez in General Forum. Last reply by Dennis Heidner May 8. 23 Replies

Polar vortex photos of ice forming INSIDE homes!

Started by Diane Chojnowski in General Forum. Last reply by Michael Cuomo May 4. 1 Reply

LEED for Homes Green Rater Training

Started by Ryan Moore in Training. Last reply by Michael Cuomo May 3. 1 Reply

Latest Activity

Danny Gough replied to Danny Gough's discussion REALLY????
"As I have read through everyone's excelent responses, it has caused me to reassess my…"
20 hours ago
Tim O'Brien replied to Danny Gough's discussion REALLY????
"Bradford - I have seen single family homes with ducted central AC or heat pump hold enough water…"
yesterday
Brett Little posted an event

How to Make Money by Cutting Your Home's Carbon Footprint, Heating Bill, and Electricity Bill to Zero - Free CE Webinar at Webinar Online

June 12, 2019 from 12pm to 1:15pm
How to make money by cutting your home's carbon footprint, heating bill and electricity bill to…See More
yesterday
Emily Ambrose posted a blog post
yesterday
Building Performance Institute commented on Emily Ambrose's blog post 4 Signs Your Website Is In Need of A Refresh
"Excellent food for thought! Thank you!"
yesterday
Building Performance Institute liked Emily Ambrose's blog post 4 Signs Your Website Is In Need of A Refresh
yesterday
Bradford E. White replied to Daniel Baur-McGuire's discussion How to Insulate Exposed Outdoor Ductwork?? Help
"One system we specify was a contractor suggestion. The "old way" was board insulation and…"
yesterday
David Keefe commented on David Keefe's video
Thumbnail

A Climate Report From The Field - Dave Keefe

"Thanks Colin, I appreciate that."
yesterday

© 2019   Created by Building Performance Association   Powered by

Badges  |  Report an Issue  |  Terms of Service