John S. Rodenhizer's Discussions

Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?

Started this discussion. Last reply by Dennis Heidner May 22. 19 Replies

I recently inspected a house that I am rating and discovered the HVAC contractor used Big 8 bubble wrap on the metal main duct in a vented attic in Climate zone 5. I spoke to the contractor about…Continue

 

John S. Rodenhizer's Page

Latest Activity

Dennis Heidner replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"Pests are also a really good reason to seal duct work with either the approved mastic OR aluminum duct tape... not the sticky "un-Duct" tape that DIYers use... "un-Duct" can be tasty for some critters..."
May 22
Mark Furst replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"Hmm, good point. I didn't notice any droppings but it could be. I'll check my other pics."
May 22
Dennis Heidner replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"If you look closely ... can you see rat or mice teeth marks on foil?   Some of the modern materials are gourmet meals for rodents.   E.g.  they really enjoy a snack on some PEX  or the insulation from some automobile…"
May 22
Mark Furst replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"On a tangentially related topic: I saw this today in an old attic installed AC system. Ducts made from only fiber-board, coming apart at the corners."
May 22
Dennis Heidner replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"I believe one of the issues is how does one defend themselves against an HVAC contractor that insists it is okay.   And the answer to that would have to be pull articles from ACCA or AHRI which say that reflective bubble wrap is worthless…"
May 20
Gabriel Perez replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"I’ll give you an a for effort but even in the best cases bubble wrap ( unless it comes with a certificate of testing and depending on what lab was used) means nothing. If you can get a engineer’s stamp with signature maybe that might…"
May 20
Paul Herron replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"I think Ed and his video hit on an important point -- these radiant barriers are primarily addressing radiant energy.  They aren't doing much to address conduction losses and, if not installed properly, will not address convection…"
May 20
John S. Rodenhizer replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"Agreed, But this guy fought me all the way. I have completed the rating and the HVAC contractor added R-8 on Top of the bubble wrap. We had to hit a HERS of 55 or below and when I gave the duct insulation R-1.1 it increased the HERS score to 57. the…"
May 20
Dennis Heidner replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"Links for Build America and Building Science…"
May 20
Dennis Heidner replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"Correct,   but when testing has been done on sealing ducts with wraps... (See the BTO and Build America website for reports... plenty of research done by ASHRAE and universities also) the seals are never really tight enough to prevent the…"
May 20
David Butler replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"@Dennis, without defending Big-8, I would point out that condensation (on duct surface) is a function of how well the vapor barrier (the outer layer) is sealed. This issue is exactly the same with conventional foil-faced fiberglass duct wrap. It,…"
May 20
Caleb Y Simon replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"I concur with your IMC interpretation. I have used this before with code officials and they have had to agree. Look forward to hearing what the "official" response is from RESNET."
May 20
Ed Fritz replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"As a radiant barrier manufacturer I've been fighting this bad information for years. I've run into this claim for installing radiant barrier in attics many times.  Which is similar the claims made for wrapping ducts.  This is a…"
May 20
Dennis Heidner replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"Read the manufacturers claims and installation steps closely  The foil needs a dead space  "To achieve a thermal resistance of R-8, 2-inch-wide spacer strips of rFOIL™ reflective foil insulation arewrapped around the duct…"
May 19
Robert Zockoff liked John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
May 16
John S. Rodenhizer replied to John S. Rodenhizer's discussion Using radiant barriers as duct insulation, Aka "Bubble wrap" What value do you assign for R-value?
"Well thank you all for your thoughts! I did receive a little feed back from the MassSave program that I work with in MA. They will not recognize radiant air barriers that count the air, only the material. They also pointed out the International…"
May 11

Profile Information

Company
JSR Adaptive Energy Solutions LLC
Role in Home Performance Marketplace
Building energy modeler, Contractor: general (new/remodel), Energy auditor / assessor / analyst
Professional Certification
HERS Rater, Other
Professional Interests
CPHC, PHIUS Rater, CPHB,and PH verifier
Website URL
http://jsradaptivenergy.com
LinkedIn Profile
John S Rodenhizer

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 8:16am on October 3, 2017, Diane Chojnowski said…

Hi John,

Welcome to Home Energy Pros Forum. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo.

Thanks!
Diane, HEP Moderator

 
 
 

Forum Discussions

HIRING TECHNICIANS!

Started by CMC Energy Services in General Forum 3 hours ago. 0 Replies

The problems with gas stoves

Started by Jacob Corvidae in Best Practices. Last reply by Diane Chojnowski on Saturday. 1 Reply

Heat and A/C on a boat

Started by Ed Minch in HVAC. Last reply by John White Jun 4. 3 Replies

Worst boiler ever?

Started by Mark Furst in General Forum. Last reply by Minnie Coleman Jun 3. 6 Replies

Where to spend my marketing dollars?

Started by Trip Smith in Marketing. Last reply by Alan Bine Jun 1. 11 Replies

How to Insulate Exposed Outdoor Ductwork?? Help

Started by Daniel Baur-McGuire in General Forum. Last reply by Ed Fritz May 23. 9 Replies

Latest Activity

Profile IconLee Blumenfeld, Joe Sanfilippo and 2 other members joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
2 hours ago
CMC Energy Services shared their discussion on Facebook
3 hours ago
CMC Energy Services posted a discussion

HIRING TECHNICIANS!

Great opportunity to join a growing company!  Now hiring Technicians who will perform energy…See More
3 hours ago
CMC Energy Services joined Diane Chojnowski's group
Thumbnail

Job Board

This group is for posting jobs related to all aspects of the home performance industry including…See More
6 hours ago
Joe Sanfilippo added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Krendl MS 1000 Spray Cellulose machine and 75KW John Deere Diesel Generator with 1998 F700

This setup is too big for our operation. Truck runs great with a cummins 5.9 and 6 speed manual…See More
7 hours ago
Ned Van Nostrand added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

2005 Ford Econoline 150

Sieda Community Action Weatherization has a 2005 Ford Van for sale.  59,900 miles.  Fairly decent…See More
9 hours ago
Lamont Thompson replied to Jimothy Whisnant's discussion 2-Minneapolis Blower Doors w/DG700’s and 2-Ductblasters w/DG700’s $5000 in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Does the $1000 cover the dg700 with the duct blaster??? Can you post pics of the equipment…"
12 hours ago
Profile IconPreston Shimer, CMC Energy Services, Lee Blumenfeld and 1 more joined Home Energy Pros Forum
19 hours ago

© 2019   Created by Building Performance Association   Powered by