ERV recommendations

Started this discussion. Last reply by Luke Langhals on Wednesday. 13 Replies

Looking for ERV recommendations for a new two level ICF residence located at 6800 ft elevation with 6001 HDD base 65 and 0 CDD base 50. Radiant floor heating only. Conditioned living space is 20,000…Continue

Tags: ERV

 

David Wentling's Page

Latest Activity

Luke Langhals replied to David Wentling's discussion ERV recommendations
"I've used the CAR II regulators before. They work, but obviously it's more mechanical moving parts that might fail overtime. I've had good success using simple adjustable diffusers. Diffusers closest to the ERV will be more…"
Wednesday
David Butler replied to David Wentling's discussion ERV recommendations
"Thanks, Luke. I agree it wouldn't make sense to design an ERV to accommodate high interior moisture loads. I think the simplest strategy for that is to not rely on an ERV to exhaust excess interior moisture, as they're not designed for…"
Sep 5
John S. Rodenhizer replied to David Wentling's discussion ERV recommendations
"As a Rater and PH guy I have seen a number of units. You do get what you pay for. I also commission for Zehnder, about 180+ to date. Having the ability to dial  in every room to meet a design spec is really special. 2 ECM fans and there…"
Sep 5
Luke Langhals replied to David Wentling's discussion ERV recommendations
"When it comes to independently ducted ERV systems operating in humid climates during the summer; the high moisture event (shower), on a single exhaust branch combines with the other exhaust streams before reaching the ERV core, this lowers the total…"
Sep 3
David Wentling replied to Ben Stallings's discussion high CO2 in a leaky house
"I would agree with Daniel's comments and question, is the device accurate. Over time sensors need to be tested and/or replaced. Utilize a dedicated gas sensor to compare results. Not sure which house you were or are in that has the high CO2…"
Aug 26
David Wentling replied to David Wentling's discussion ERV recommendations
"Thank you for all your comments. House is ICF and local code is 2018 IECC listing maximum 3 ACH50. Depending on zone and shielding selected ACH averages out about 108 CFMnatural. ASHRAE 62.2 calculation indicates 32 CFM continuous required (3 beds,…"
Aug 26
Daniel Baur-McGuire replied to David Wentling's discussion ERV recommendations
" I second Luke's recommendation for Panasonic, RenewAire, Zehnder, or Venmar (Broan). All good units with humidity recovery. Hook through bathrooms to encourage humidity retention. I personally would choose a Panasonic or Zehnder. The…"
Aug 26
David Butler replied to David Wentling's discussion ERV recommendations
"@Luke, since you work for a well-known ERV manufacturer, I'm curious if you have access to latent performance data (other than the single point @ summer conditions typically published). A graph would be ideal. I think most practitioners fail to…"
Aug 22
Luke Langhals replied to David Wentling's discussion ERV recommendations
"Hello David -- Do you have an expected air tightness? What type of blower door test results are you projecting? David is right; you should be using a low flow range hood of 300 cfm with good capture rate. Without an account for how that air will be…"
Aug 22
Brad Cook replied to David Wentling's discussion ERV recommendations
"Many ERVs, particularly those with enthalpic wheels, use only ONE motor to run two fans. The In/Out are balanced with dampers. The ASHRE standards are guidelines. The installed ventilation system should be capable of moving at least the amount of…"
Aug 22
Robin Henry replied to David Wentling's discussion ERV recommendations
"Unfortunately I don't have anything to add here but wanted to give this post a bump as I'm a BPI Building Analyst and I'm trying to learn more about what ERV/HRV can accomplish as well as their installation. For what it's worth…"
Aug 22
David Butler replied to David Wentling's discussion ERV recommendations
"I think you're overreacting to the need for humidity control in your location. If indeed there's a need to remove any moisture, an ERV is the least effective way to do that. Moreover, I advise against locating an ERV supply in a closet, as…"
Aug 21
David Butler replied to David Wentling's discussion ERV recommendations
"test"
Aug 20
David Wentling replied to David Wentling's discussion ERV recommendations
"Thank you for the insight David. House only has the first level walls poured, second level floor installed and they are stacking the second level ICF now. Blower door test is some time away. Need to design ventilation based on assumptions and tune…"
Aug 20
David Butler replied to David Wentling's discussion ERV recommendations
"I generally recommend against using an ERV as primary ventilation for bathrooms & laundry since the enthalpy core acts to minimize moisture transfer from "high to low" (referring to partial vapor pressure of outdoor and indoor air).…"
Aug 20
David Wentling posted a discussion

ERV recommendations

Looking for ERV recommendations for a new two level ICF residence located at 6800 ft elevation with 6001 HDD base 65 and 0 CDD base 50. Radiant floor heating only. Conditioned living space is 20,000 cf per level plus small amount of conditioned attic due to foaming the roof deck. Lower level is walkout on one side and buried on three. Upper level has garage attached on one side only.Using total volume * 0.35 ach / 60 min/hour = ~120 cfm flow per level. There are two baths and laundry per level…See More
Aug 20

Profile Information

Company
ConservFirst
Role in Home Performance Marketplace
Educator / Trainer, Energy auditor / assessor / analyst
Professional Certification
BPI, Other

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 11:27am on October 4, 2017, Diane Chojnowski said…

Hi David,

Welcome to Home Energy Pros Forum. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo.

Thanks!
Diane, HEP Moderator

 
 
 

Forum

Air Sealing Manufactured Home

Started by John Lile in General Forum. Last reply by Darin Pleines 19 hours ago. 10 Replies

Solar ROI Calculator

Started by Kyle Baker in General Forum 21 hours ago. 0 Replies

Does Radiant Barrier Still Work 10 Years Later?

Started by Green Energy of San Antonio in General Forum. Last reply by Sean Wiens on Friday. 2 Replies

Best Exhaust Fans - your opinion?

Started by Eric Miller in General Forum. Last reply by Russell Pope on Thursday. 3 Replies

October 2 is Energy Efficiency Day

Started by Diane Chojnowski in General Forum on Thursday. 0 Replies

ERV recommendations

Started by David Wentling in General Forum. Last reply by Luke Langhals on Wednesday. 13 Replies

Baffles without soffit vents?

Started by Haley Keegan in Best Practices. Last reply by Eric Kjelshus Sep 9. 14 Replies

Off-Grid Applications?

Started by Kyle Baker in General Forum. Last reply by Paul Scheckel Sep 5. 2 Replies

Latest Activity

Profile IconKevin M Dugan, Daniel Haydon and Patty Hoffman joined Home Energy Pros Forum
18 hours ago
Darin Pleines replied to John Lile's discussion Air Sealing Manufactured Home
"In illinois WAP program we seal the belly material and lightly dense pack the cavity with loose…"
19 hours ago
Brian Robinson replied to John Lile's discussion Air Sealing Manufactured Home
"The first place to look when working on trailers / manufactured home is the…"
21 hours ago
tedkidd replied to John Lile's discussion Air Sealing Manufactured Home
"Spray foam the road barrier."
21 hours ago
Tom Wilson replied to John Lile's discussion Air Sealing Manufactured Home
"The good news is the linoleum IS the air/vapor barrier and unless it is put under 50 Pa negative…"
21 hours ago
Kyle Baker posted a discussion

Solar ROI Calculator

How do you know when you get a payback on installing a solar system? What ROI have you received…See More
21 hours ago
Robin Henry replied to John Lile's discussion Air Sealing Manufactured Home
"Sorry if I'm preaching to the choir but careful sealing up mobiles too tightly as they are…"
22 hours ago
Tom Wilson replied to John Lile's discussion Air Sealing Manufactured Home
"Typo corrections: This is the classic problem folks have been wrestling with forever with…"
22 hours ago
Ed Minch replied to John Lile's discussion Air Sealing Manufactured Home
"Many of the WAP programs have written extensively on sealing of these guys.  West Virginia in…"
22 hours ago
Tom Wilson replied to John Lile's discussion Air Sealing Manufactured Home
"This is the classic problem folks have been wrestling with forever with manufactured…"
22 hours ago
Rich Mialki Jr replied to John Lile's discussion Air Sealing Manufactured Home
"Does this really matter much?  Think of what the blower door is doing as opposed to natural…"
22 hours ago
Emily Ambrose's blog post was featured
yesterday

© 2019   Created by Building Performance Association   Powered by

Badges  |  Report an Issue  |  Terms of Service