Convert BTU/hr in a Manual J to actual fuel usages

Started this discussion. Last reply by Richard McGrath Jul 25. 17 Replies

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using…Continue

 

Dan Wise's Page

Latest Activity

Building Performance Institute liked Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
Aug 1
Richard McGrath replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"             Estimated Fuel usage  formula .   Been using for years and has yet to be more than 5 - 10 % off .                ( Htg Load x 24 x degree days x correction factor )                …"
Jul 25
Eric Kjelshus replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"I do a heat loss/gain each "bid"  some times 3 ways.   I like to use fuel usage with a good program. If not use are going to be off.    find a person who is big big and middle age they will take more AC and less…"
Jul 21
Eric Miller replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Folks Elite Software, in their suite of products (which also includes a full Manual J8 product) has a tool called "Energy Audit" which models energy use very nicely. It is kinda pricey though. I used it a lot when I was wearing a…"
Jul 18
Franco Oyuela replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"B-T-U https://www.heatingair.orgThe acronym stands for British Thermal Unit, which is the unit used to measure thermal (heat) energy. Specifically, it is the amount of energy needed to raise 1 pound of water 1°F at sea level. When used in…"
Jul 15

Profile Information

Company
Grand Design Group
Professional Certification
CGP
Professional Interests
National Green Building Standard consulting and verification services.
Construction Management and Project Planning
Website URL
http://www.granddesigngroup.us

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 4:32pm on June 29, 2014, Diane Chojnowski said…

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to add your profile photo and be sure to put your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Forum

Latest Activity

Building Performance Association posted a blog post

August Policy & Advocacy Updates

By: Lizzie Bunnen, Government Affairs Director, AnnDyl Policy Group…See More
20 minutes ago
Building Performance Association commented on Emily Ambrose's blog post 6 Building Conferences We’re Attending
"Great picks! Thanks for including us!"
35 minutes ago
Building Performance Association liked Emily Ambrose's blog post 6 Building Conferences We’re Attending
35 minutes ago
Diane Chojnowski's 2 videos were featured
4 hours ago
Brad Cook replied to Chris Stratton's discussion Okay to use 1" polyiso as a insulation base for 50 gallon heat pump water heater?
"Not all insulation is the same. For example, Dow's Super Tuf-R polyiso has a compression…"
5 hours ago
David Butler replied to David Wentling's discussion ERV recommendations
"@Luke, since you work for a well-known ERV manufacturer, I'm curious if you have access to…"
13 hours ago
Luke Langhals replied to David Wentling's discussion ERV recommendations
"Hello David -- Do you have an expected air tightness? What type of blower door test results are you…"
15 hours ago
Brad Cook replied to David Wentling's discussion ERV recommendations
"Many ERVs, particularly those with enthalpic wheels, use only ONE motor to run two fans. The In/Out…"
17 hours ago