From Control Layers to High-Performance Enclosures - Free CE Webinar

Event Details

From Control Layers to High-Performance Enclosures - Free CE Webinar

Time: May 29, 2019 from 12pm to 1:15pm
Location: Webinar Online
Website or Map: https://www.eventbrite.com/e/…
Event Type: webinar, ceus
Organized By: Brett Little
Latest Activity: May 20

Export to Outlook or iCal (.ics)

Event Description

High-performance enclosure systems are fundamental to efficient, durable, healthy, sustainable, and resilient homes -- especially in demanding climates. This session will dive into the critical functions and attributes of the four key control layers: thermal, water, air, and vapor. Then using these principles, we will look at leading high-performance enclosure strategies and along with specific applications for slab, foundation, wall, and roof assemblies.

Continuing Education Units (CEUS) 1 hour in

Green Building Certificate Institute (GBCI)
Building Performance Institute (BPI) NonWholeHouse
American Institute of Architects - AIA (HSW) 
Certified Green Professional (NARI & CGP)
Certified GreenHome Professional (CGHP)
AIBD

State Architect / Builder License may be applicable

Lessons Learned

- Understand the critical role and attributes of thermal, water, air, and vapor control layers
- Understand the critical relationship between layers and the importance of the order or sequence of the layers
- Be able to identify each control layer on the construction drawings
- Recognize the proper application of these layers to a slab, foundation, wall or roof assembly


Session sponsor:

Tstud - Save money, stop thermal bridging and reduce energy usage. All in 1.



Instructor: Patrick Huelman - University of Minnesota 

Pat Huelman is an Associate Extension Professor in Energy and Building Systems with the University of Minnesota's Department of Bioproducts and Biosystems Engineering and serves as Coordinator of the Cold Climate Housing Program with the University of Minnesota Extension. He is a lead faculty member for the Building Science and Technology undergraduate degree program and a principal investigator for hygrothermal testing at the Cloquet Residential Research Facility. Currently, Pat is the Project Lead for NorthernSTAR, one of the Department of Energy's Building America teams.

Pat has been extremely active in professional education for the home building industry and is nationally recognized for his "systems approach" to improving overall home performance. Pat's long-term focus has been on heat, air, and moisture movement in buildings and his primary expertise is in building systems and technologies that will provide energy efficiency, long-term durability, and healthy indoor air for homes. With more than 30 years in the field, Pat brings extensive experience and expertise in energy-efficient design and construction, innovative building systems, moisture management strategies, mechanical ventilation, and residential indoor air quality.

Comment Wall

Comment

RSVP for From Control Layers to High-Performance Enclosures - Free CE Webinar to add comments!

Join Home Energy Pros Forum

Attending (1)

Latest Activity

Profile IconChris Crawford, Jerry Herron, Baker Electric Home Energy and 1 more joined Home Energy Pros Forum
1 hour ago
Dennis Heidner replied to John Lile's discussion Air Sealing Manufactured Home
"Yup,  I'm not sure you want to even try tightening up a modular home built before…"
12 hours ago
Dennis Heidner replied to John Lile's discussion Air Sealing Manufactured Home
"You made some very important observations. It's really important to think about how tight you…"
12 hours ago
Tom Wilson replied to John Lile's discussion Air Sealing Manufactured Home
"Unless the home is on a permanent block or concrete foundation, attempting this is a lost cause.…"
12 hours ago
Tom Wilson replied to John Lile's discussion Air Sealing Manufactured Home
"Actually, it was only in 1976 that any standards at all were applied to mobile homes:  U.S.…"
12 hours ago
Dennis Heidner replied to John Lile's discussion Air Sealing Manufactured Home
"You didn't mention anything about the age of these homes.  Early mobile/modular homes…"
12 hours ago
David Butler replied to John Lile's discussion Air Sealing Manufactured Home
"Notwithstanding the typical low budget for these homes, it seems like encapsulating the crawl might…"
13 hours ago
Chris Clay replied to John Lile's discussion Air Sealing Manufactured Home
"Thanks Ed, Yes the duct system is outdoors. It came from the factory that way. After working on…"
17 hours ago
Ed Minch replied to John Lile's discussion Air Sealing Manufactured Home
"Chris I agree, and then notice that puts the duct system outside of the house.  So the duct…"
17 hours ago
Home Energy Magazine posted an event
Thumbnail

Getting to Zero Forum: OCTOBER 9-11, 2019 OAKLAND, CALIFORNIA at Oakland, California

October 9, 2019 at 6pm to October 11, 2019 at 7pm
The Getting to Zero Forum is a solutions-based event Dedicated to zero energy and zero carbon…See More
21 hours ago
Chris Clay replied to John Lile's discussion Air Sealing Manufactured Home
"Hi John, The primary air barrier of all mobile home is the subfloor and that is what should be air…"
21 hours ago