Duct Testing Training & Certification Online - 2009/2012 IECC Code Compliance

This is a sample video taken from the Duct & Envelope Tightness Verifier online training and certification class.

The DET Verifier training provides the student with the background building science information required to perform duct testing and blower door testing, as required by the 2009 and 2012 IECC residential building code.

The training also includes step-by-step training on the Retrotec and Energy Conservatory testing equipment. For more information, check out our website: https://homeenergypartners.com/training/hvac-training/duct-envelope-tightness-verification-training-for-energy-code-compliance/

Views: 106

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Latest Activity

John White posted a blog post
27 minutes ago
Profile IconChristina Mathieson, Sophia Jones and Nancy Hawkins joined Home Energy Pros Forum
yesterday
Brett Little posted an event
Thumbnail

Duct Optimization and Performance - Free CE Webinar at Webinar Online

October 31, 2018 from 12pm to 1:15pm
Good indoor air starts with proper duct design and installation. In residential ventilation…See More
Friday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"Thank You, Colin!  Those are very good points and processes to do some Zone Pressure…"
Friday
Colin Genge replied to Jerry Needham's discussion Blower door test for small apartment building
"The way we'd normally do this is to mount one blower door in the hallway, then a duct tester…"
Friday
Scott Katznelson replied to Jerry Needham's discussion Blower door test for small apartment building
"Most of the work I do is retrofit of older buildings. Marriage wall leakage is often significant,…"
Thursday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"Scott Katznelson   In 2013,  I had my HERS Field Review completed on a multi-family…"
Thursday
Sean Lintow Sr replied to Jerry Needham's discussion Blower door test for small apartment building
"Sorry but LMAO - one blower door for that small of a space gives you an accurate number for the…"
Thursday
Chris Davis posted a blog post
Thursday
Scott Katznelson replied to Jerry Needham's discussion Blower door test for small apartment building
"The most accurate way to accomplish this is to have 4 blower doors running at the same time, one…"
Thursday
Brett Little posted a discussion

Tour 2 IL New Built Homes - 1 LEED Silver - 1 Zero Energy Ready

During the IL Green Built Home Tour, we looked at 2 homes right down the road from each other to…See More