Controlling Airflow in Existing Dwellings

The new concept of "controlling airflow" is discussed with a Savings-to-Investment Ratio (SIR) calculated. Controlling airflow includes 1) air sealing to red...

Views: 120

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Rick Karg on June 26, 2014 at 12:04pm

David, I am the guy who put together and narrated the video.I am sorry you missed the section in the video about increased heating load resulting from ventilation, which was 6.4 therms (slide 9). I did mention the increased cooling load, but did not include it in the SIR calculation because of the location; Portland, Maine, where cooling is a minor issue. If you use this analysis in a heating/cooling climate, both the heating and cooling load increases from ventilation should be included in the SIR equation numerator. The RED Calc Free Advanced Infiltration tool reports both heating and cooling loads.

Regarding maintenance, you are correct, I did not include any maintenance costs. If these were included they would be subtracted from the numerator as a recurring annual cost and would lower the SIR value. I ignored these costs because we don't have a good idea of what they are. Of course, there will be some homeowner work involved, such as cleaning the ventilation fan blades, etc. We hope to get a better idea of maintenance costs for ventilation systems within the next five years or so.

It is best practice to add ventilation to each room using ductwork, as you suggest, but it is not required by the ASHRAE 62.2 standard. I assumed a high quality exhaust fan installed in a centrally located bathroom would provide local and whole-building ventilation (this complies with ASHRAE 62.2). If the ventilation system is more complex, the cost of installation would increase. This would, of course, impact the SIR value. A ventilation system that distributes fresh air evenly throughout a home is preferred. However, it is common that this best-practice solution will not fit into the project budget, especially for the folks working within the low-income weatherization program.

Comment by David Eakin on June 26, 2014 at 11:20am

You did not add the (other) expected yearly running costs for the ventilation unit (additional air conditioning costs for heat/coll/dehumidify, any replacement parts/service, etc.) in the initial SIR computation; you only talk to the fan electrical costs. Also note: if the structure does not already have duct work (a very common occurrence in older buildings) the additional ventilation duct work costs make this proposal very costly, and assuming a single exhaust fan will provide adequate ventilation to each individual occupied room - especially with closed doors - without dedicated duct work is problematic regardless of what the ASHRAE prescriptions preach. It is the reason why paired supplies/returns are the best way to deliver conditioned air to each occupied room vs. central supplies/returns.

Forum Discussions

Psychrometric Chart Training

Started by John Krochmalny in Training 7 hours ago. 0 Replies

Too many Heat Pump Water Heaters in a basement?

Started by Brad Cook in General Forum. Last reply by Michael Duclos 13 hours ago. 10 Replies

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler on Monday. 2 Replies

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco on Monday. 1 Reply

Latest Activity

B Eric Bell liked Bob Krell's group Healthy Indoors (IAQ)
4 hours ago
John Krochmalny posted a discussion

Psychrometric Chart Training

Looking through the various areas of this site, I didn't see too much information or training on…See More
7 hours ago
Profile IconMike Malek, Avery T. Phillips and Sarah Burger joined Home Energy Pros Forum
8 hours ago
Dannie Jackson's blog post was featured

Core Heat And Other Concepts

  In some places the use of solar heated liquids from hot water solar panels are used to provide…See More
13 hours ago
Michael Duclos replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"I’ve been looking into Sanden for a multi-family PH near Laconia, NH, ASHRAE 99.6% temp is…"
13 hours ago
Profile IconTroy Spindler, Mike Berg, Andrew McDowell and 4 more joined Home Energy Pros Forum
yesterday
David Butler replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"theoretically, let's say you perfectly isolate the HPWH from a heat source. The HPWH's…"
Monday
David Butler replied to David Butler's discussion How would you insulate this roof?
"Interesting idea. Commercial roof on a slope! Typical density for roofing spray foam is 2.5 to 3.0…"
Monday

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service