1950s Home Retrofit to Super Efficient Passive House - Urban Green Building

This 1950s Montreal house was retrofitted to become a super efficient passive house by adding a 16 inch thick layer of cellulose insulation to the exterior. Maison Ozalée's builder, Richard Price from Construction Le Tournesol, also used triple glazed windows with insulated frames, and strategically placed small windows on the north side of the building to reduce heat loss, and placed large windows on the south side to take advantage of solar gain, which helps heat the house in winter. In order to avoid overheating the house in the summer, there are built-in shading elements above the large south-facing windows.

The home is airtight, with plywood sheathing to solidify the older home doubling as a vapour barrier once all the seams were taped.

Because of the energy gained from passive solar, and because it's airtight, this home only needs approximately 10% of the energy a typical home of the same size would need to heat during the winter.

The owners are very environmentally conscious and added additional features to their home to make it sustainable not just in terms of energy, but water as well. They installed a rainwater catchment system that feeds water into an underground water cistern which they use to water their enormous permaculture garden. They use no municipal water to irrigate their plants.

Indoors, they've installed a grey water recycling system that allows them to filter and clean water from the shower & bath and then reuse it a second time to flush their toilets.

It was really interesting to see how this alternative building technique can result in such enormous energy savings! And to see that an existing home can fairly easily be retrofitted to be more energy efficient!

Views: 49

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Latest Activity

Daniel Baur-McGuire replied to Tim Kendzia's discussion Cooling effect from solar panels
"I would argue that keeping the solar panels cool is more important as you will produce more power.…"
3 hours ago
Daniel Baur-McGuire replied to David Meiland's discussion Air gap above floor insulation--how big is the impact?
"Im specifically thinking of floors over garage. Builders here often use rigid insulation under the…"
3 hours ago
Robert DV replied to David Meiland's discussion Air gap above floor insulation--how big is the impact?
"Why Charles!   How do you really feel??"
3 hours ago
Robert DV replied to David Meiland's discussion Air gap above floor insulation--how big is the impact?
"David, Assuming the band / rim is sealed what benefit is there to direct contact with the sub…"
4 hours ago
Sean Lintow Sr replied to David Meiland's discussion Air gap above floor insulation--how big is the impact?
"2018 IECC --- just think, you do have 6 sided encapsulation unlike an attic which see's more…"
18 hours ago
Mick Lane replied to David Meiland's discussion Air gap above floor insulation--how big is the impact?
"There are a few things going on here. First, if you want an idea of the effectiveness of the…"
18 hours ago
Daniel Baur-McGuire replied to David Meiland's discussion Air gap above floor insulation--how big is the impact?
"Where is this written? please and thank you. As, its written you would have to do cont. insulation…"
18 hours ago
Charles Buell replied to David Meiland's discussion Air gap above floor insulation--how big is the impact?
"Of course---and fiberglass is garbage in this application and many others"
19 hours ago

© 2018   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service