The Ductless Mini-Split Heat Pump's Big Brother - CITY MULTI

In my last four HVAC Design jobs, I've specified ductless mini-split heat pumps. I have four more such jobs underway now.

Why mini-splits?

  • Efficiency (up to 26 SEER)
  • Variable Refrigerant Flow
  • Versatility
  • No Ducts!
In fact, some say they're threatening to replace the standard forced air HVAC systems that we've grown to lo...well, that we've grown accustomed to. Allison's post about the advantages of these mini-split heat pumps explains some of the other reasons why they're becoming so popular. 

Diamond Designer

At a recent Mitsubishi Diamond Designer training, I learned more about the mini-split's big brother, the CITY MULTI system by Mitsubishi Electric HVAC, and how to design it for multi-family and commercial buildings. It uses the same efficient technology as mini-splits, but on a larger scale. In fact, we recently looked at a 250-unit high rise condominium retrofit project where CITY MULTI would replace a tired, inefficient boiler and chiller system from the 1960's. CITY MULTI's pipes are no bigger than 3" with insulation, so the lines will be small enough that the team won't have modify the structure much at all.

The WHAT and the HOW

CITY MULTI is a 2-pipe, modular heat pump system that takes advantage of special compressors that can feed up to 50 different zones. It also can do simultaneous heating and cooling.

The 2 pipes are the refrigerant lines that run from an outdoor condensing unit to either a BC Controller or Branch Header. From there, soft copper, pre-insulated line-sets are used to deliver the cold or hot refrigerant to individual fan coils that are placed within each zone that requires heating or cooling.  With the simultaneous heating and cooling system, the same refrigerant which is used to heat one zone can be pumped to another zone with a need for cooling.  This offers both increased energy efficiency and comfort over other types of HVAC systems.

Depending on the series (R2, WR2, Y, WY, H2i, & S), systems can be designed for up to 30-tons of capacity, using  6, 8, 10, or 12-ton modular condensers piped  together. These systems can also have over 100% connected capacity, in some cases up to 150% of their condensing unit rated capacity because of the systems greatest asset: Variable Refrigerant Flow/Volume (VRF or VRV).

VRF/VRV allows a system to adjust the amount of refrigerant delivered by the compressors to provide only the amount of heating or cooling to a zone that is required at any given time within the limits of the designed peak load. It does this through the use of a Linear Expansion Valve (LEV) that controls the refrigerant flow to each indoor unit. Through 3 on-board thermistors, the indoor unit constantly monitors the space and refrigerant conditions and communicates to the LEV and the condensing unit to dial up or down the amount of refrigerant delivered to the coil.

Controls vary as well but are very simple and integrated with the system. The indoor units can be controlled individually, by a central master controller, both, or by a PC-based system. Because the thermostats are within the indoor units, or heads, temperature is controlled remotely and the controls can be placed anywhere within the zone. They can be used to read the temperature in the room but are NOT a thermostat.

The Advantages

  • Certain models offer 100% heating capacity down to 5° F.  All the units are heat pump models that provide substantial low ambient heating capability typically eliminating the need for additional heating systems in most of the Southeast and even much farther north if properly designed.
  • The inverter driven compressor uses only as much or as little energy as needed at any given point in time to maintain room conditions.  This results in energy savings that have been in the range of 10% to 40% over other systems (based on actual retrofit results and project energy models)
  • R-2 and Y series systems are compatible with both air cooled and water cooled configurations, and the water-cooled equipment CAN be used with geothermal applications
  • Indoor fan coil options range from floor, wall, and ceiling mounted to floor, wall and ceiling concealed (ducted).
  • Using their new Hydronic Heat Exchanger and Booster units, hot water can be created directly or through the use of recovered energy from cooling for large potential energy savings.
  • Offers completely integrated ventilation options between 300 and 1200 CFM.
  • First cost is competitive with water source heat pump systems and is better than four-pipe and geothermal systems.

In addition to commercial and multi-family projects, this could potentially be a great application in larger homes that have loads greater than 5 tons (and available 3-phase power). 

 

from the desk of Energy Vanguard's "Diamond Designer"

 

Views: 2470

Tags: Cooling, Design, Duct, HVAC, Heat, Heating, Multi-Family, Pump, and

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Franco Oyuela on July 19, 2018 at 12:26pm

The compact design and long piping system gives homeowners free reign for designing a ductless system to their project’s needs, rather than accommodating bulky ducts. Versatile uses for so many applications is one of the reasons ductless systems are so popular.

Comment by tedkidd on May 19, 2011 at 11:57am

Cool, Didn't realize there were fresh air options (nice to have ONE solution...)

"Offers completely integrated ventilation options between 300 and 1200 CFM."

where do you get more information about the ventilation.  

 

Forum Discussions

VERY TIGHT HOME WITH OVER SIZED AC

Started by Jerry Needham in BPI. Last reply by Dave Taylor on Thursday. 6 Replies

Mini split air conditioners and ceiling fans

Started by Beverly Lerch in General Forum. Last reply by Daniel Baur-McGuire Aug 13. 4 Replies

DIY Filter Solution for an Evaporative Cooler, anyone?

Started by Leslie Jackson in HVAC. Last reply by Daniel Baur-McGuire Aug 13. 6 Replies

Apply now for the Jon Siemen Memorial Scholarship!

Started by Diane Chojnowski in General Forum. Last reply by Quinn Korzeniecki Aug 9. 1 Reply

Latest Activity

Brett Little posted an event
Thumbnail

Green Rater LEED Credential Online Training at Online

September 5, 2018 at 12pm to September 6, 2018 at 5pm
With over 450,000 LEED® for Homes™ spaces worldwide, LEED is the international rating system to…See More
Saturday
Michael Schettine commented on Michael Schettine's video
Thumbnail

AccuFrame Water Test

"The Like button doesn't work on this site..."
Saturday
Franco Oyuela commented on Mike Muras's blog post "Practical Standards to Measure HVAC System Performance" Rob "Doc" Falke 04/17/2006
"It's important to evaluate and inspect a system regularly to make sure it's at optimal…"
Friday
Seventhwave posted an event

HVAC technology enhancements for energy conservation at The Marq

October 4, 2018 from 8:30am to 4pm
Join us to learn how to get the largest energy savings in your commercial buildings. HVAC as a…See More
Friday
Peter Krych replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"I agree, it is wasteful to remove and dump old insulation. I still does its job. Air sealing is…"
Friday
Michael Schettine commented on Michael Schettine's video
Thumbnail

AccuFrame Water Test

"With the conversion rate that- air is 800 time LESS dense than water at sea-level…"
Friday
Michael Schettine posted a video

AccuFrame Water Test

In this short video, water is used to visualize air leakage sites that are present in the majority of framed walls in the US. New regulations require better ...
Friday
Sam Feder liked Dav Camras's discussion Adding blown insulation to poorly installed batts?
Thursday
Chris Stratton liked Don Fugler's discussion Choosing a range hood
Thursday
Dave Taylor replied to Jerry Needham's discussion VERY TIGHT HOME WITH OVER SIZED AC
"Jerry, you should look at Buildingscience.com" High Mass Walls" 105 paper for more…"
Thursday
Jill Lindman's 3 events were featured
Thursday
Jill Lindman posted events
Thursday
Diane Chojnowski posted videos
Thursday
Don Fugler replied to Don Fugler's discussion Choosing a range hood in the group Kitchen Ventilation
"Has anyone installed a range hood in an older home with the ducting down to the basement and out…"
Thursday
Profile IconEileen Kraus-Dobratz, VENI MITTAL and Mark A McCrumb joined Home Energy Pros Forum
Thursday
Brian Robinson replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"YES, YES, & YES!!! Bat droppings, mouse droppings, dead mice, nuts, seeds, acorns, lack of…"
Wednesday
Matt Peterson posted a blog post

The Importance of keeping Professionally Trained Gas Line Installation Technicians happy and loving their jobs!

Our company is very much a family to us, we strive to bring in and develop great people into great…See More
Wednesday
Profile Iconyanky fogel, Kathleen Krebs, Nicholas Rubenstein and 3 more joined Home Energy Pros Forum
Wednesday
yanky fogel liked Home Energy Magazine's video
Tuesday
Franco Oyuela commented on Shawn Weeks's blog post How Homeowners Can Keep Electricity Costs Down in Summer Months
"Cutting back on air conditioning is also good for the environment because it reduces carbon…"
Tuesday

Photos

  • Add Photos
  • View All

© 2018   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service