Ridge Vent . . . and Nothing But the Ridge

Can anyone convince me that this picture shows anything other than the fact that the ventilation provided here is effective only in the first five inches down from the ridge? And yes, there is continuous soffit venting that is baffled and open to the outside.

Views: 14288

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Bob Mariani on December 29, 2011 at 6:30pm

Still more natural air flow should persist.  I believe the soffit venting is insufficient.  The air movement should be equal between the ridge and the soffit vents.

Comment by Ed Voytovich on December 29, 2011 at 5:55pm

Bob . . . I'll refer to the black snot as "mildew" in hopes of assuaging to the extent possible the anxiety of the homeowners and the desire of their lawyers for a new Mercedes.   

Thanks for pointing out the fact that the cut-out is somewhere around an inch or less on each side instead of the manufacturers' recommended inch and a half.  Still, could another 3/4" on each side make that great a difference?

There are no gable end vents, and the same pattern of mildew extends the entire length of the ridge.

I suspect that this condition is more typical than not of ridge vents.  When the wind blows across the roof  and the ever-popular Bernoulli's Law (http://scienceworld.wolfram.com/physics/BernoulliEffect.html) comes into play, the downwind side of the vent sucks air out of the attic.  I suspect that it is most likely to take the makeup air from the nearest source (which is the other side of the ridge) than from either gable vents or vents in the soffit.  My thinking is that the high-moisture conditions in this particular house created an interesting experiment, but I am grateful for other thoughts and possibilities.

Comment by Bob Mariani on December 29, 2011 at 4:52pm

Ed, is that mold on the discolored section of the sheathing?  The vent opening should have been larger.  Only a small air flow is occurring.  Also be sure no gable vents are still opened that will short circuit the soffit to ridge vent airflow.

Forum Discussions

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler 3 hours ago. 34 Replies

Psychrometric Chart Training

Started by John Krochmalny in Training. Last reply by Mahendra Shah on Friday. 1 Reply

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco Oct 16. 1 Reply

Latest Activity

David Butler replied to David Butler's discussion How would you insulate this roof?
"Sean Lintow proposed rails and clips (re: first comment in this discussion), but in the context of…"
3 hours ago
Brad Cook replied to David Butler's discussion How would you insulate this roof?
"I missed where the suggestion for rails came in. The plywood would not need any rails. 4+ inches is…"
7 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"I'm a little confused about the necessity and purpose of using support rails if working on…"
7 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"If you insulate master bedroom and family room from below, you definitely need more R-value than…"
7 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"Brad, I was only talking about using EPS between the ridges, if necessary, to conform to bolts.…"
7 hours ago
Brad Cook replied to David Butler's discussion How would you insulate this roof?
"It kind of depends on the PIC. Not all insulation is made the same. Here in VT (and all of New…"
7 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"Filling those shallow valleys with rigid foam not only prevents primary foam panels from…"
8 hours ago
Brad Cook replied to David Butler's discussion How would you insulate this roof?
"Bill, you just posted a number of responses in different areas of the thread. I will try to respond…"