John Tooley said, “Air is like crooked rivers, crooked people, teenagers, and cheap labor.  It always seeks the path of least resistance.”  He didn’t say that Angry air is Noisy air.   Air doesn’t like being forced through corrugated, flexible ducting, pushed around corners, and made to force open dampers.  It resists being made to perform in a way that it doesn’t want to.  It takes more and more force as the resistance increases.  Air is just fine when you just let it move at will.  It can become amazingly strong as any building that has met a hurricane or tornado can attest to.  And as objects like asteroids and space capsules hurtle through the atmosphere they burn up!

ASHRAE 62.2 requires bathroom fans to make no more noise than a quiet refrigerator in a quiet kitchen: 1 sone or less.  And if you put an Energy Star bathroom fan on the bench and plug it in, you can barely hear it.  It’s amazingly quiet.  “Is it running?” people ask.  And it is.  So how come once you install the fan in the ceiling it gets uncomfortably loud?

Fan manufacturers not only made these fans quiet, they put DC motors in them that are extremely tolerant ofchanges in pressure.  As the pressure increases in the installation, the fan motor compensates by using more power to increase the speed of the spinning wheel that is pushing the air.  (Notice the curve on this graph that starts on on the left side and then drops off the cliff at about 75 cfm.  It has about the same airflow from 0.45 iwg as it does at 0.0 iwg!)  That’s a wonderful thing because people can install the fans horribly and step on the duct and lots of other nasty things and still come out with the same airflow . . . but not the same sound level.  What was really, really quiet is now uncomfortably loud.  And as houses get tighter they get quieter and a noisy fan is annoying which is why so much effort was made to get them quiet so they could run all the time without bothering anyone!

I have found that builders get aggravated because these quiet and expensive fans that they have been compelled to install really aren’t all that quiet.  And they should be quiet.  They have been designed to be quiet.  Tested to be quiet.  And if you disconnect them from the installation, they are quiet.

So here’s a simple way to determine if the fan is working right: listen to it.  If the air is angry, it will be noisy and noisy DC fans equal bad installation.  The air is yelling at you.  I have found ducts filled with the foam that was sprayed on the house for insulation.  Backdraft dampers remain taped closed.  Ducts terminated against a wall or floor in the attic and don’t actually get to the outside.  If a bathroom fan that is rated to be < 0.3 sones is noisy, its a bad installation.  Period.  Fix it.  It may still be moving enough air to meet the ventilation requirements, but if it is noisy the homeowner will find a way to turn it off and stuff it full of socks.  Then the air in the house will get bad and people will get sick.  And the occupants will get angrier than the air!  And the really dumb thing is that all these codes and standards and mathematical computations and formulas to size the fan correctly mean absolutely nothing if the fan is turned off.

Views: 221

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Forum Discussions

ENERGY STAR Version 3

Started by Allison A. Bailes III in General Forum. Last reply by Mandy Leazenby 1 hour ago. 10 Replies

Blower door test for small apartment building

Started by Jerry Needham in General Forum. Last reply by John White on Friday. 9 Replies

Radiant Barrier Southeast

Started by Gary Wright in Best Practices. Last reply by yassin chahdi on Thursday. 6 Replies

Latest Activity

Mandy Leazenby replied to Allison A. Bailes III's discussion ENERGY STAR Version 3
"I've only ever worked on Energy Star with Habitat for Humanity.  But we have very few…"
1 hour ago
Colin Genge is now a member of Home Energy Pros Forum
2 hours ago
Brett Little posted a discussion

How to become a Certified GreenHome Professional - Free Webinar!

The Certified GreenHome Professional (CGHP) training is a way to learn about the basics of…See More
22 hours ago
Corbett Lunsford's video was featured

Testing Air Quality with Your Nose: Control Your HOMEChem

Charlie Weschler sits down with Grace and Corbett and gives fascinating examples of the complexity of indoor air chemistry. He is an air quality legend, a professor on three continents, and a super nice guy.
Friday
Profile Iconwallace van, Tony kroos and Sunmar Construction, Inc joined Home Energy Pros Forum
Friday
John White replied to Jerry Needham's discussion Blower door test for small apartment building
"Well, I think it completely depends on the purpose and requirement of the test. Testing one unit in…"
Friday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"I can use my Duct Blaster on any house that I expect to be less than 1300 CFM through the…"
Friday
Sean Lintow Sr replied to Jerry Needham's discussion Blower door test for small apartment building
"FYI, he is in Illinois where code is 5 (well up until March as noted when it drops to 4)  Heh…"
Friday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"Here are two pictures of the duct blaster fan as a blower door.  1 in a door and 1 in a…"
Thursday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"What standard are you testing to? Energy Star requires 5 ACH @ 50.   Code is 3.0 etc…"
Thursday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"What standard are you testing to? Energy Star requires 5 ACH @ 50.   Code is 3.0 etc…"
Thursday
Franco Oyuela replied to Allison A. Bailes III's discussion ENERGY STAR Version 3
"The ENERGY STARnew homes program has been around since the mid-1990s and is currently undergoing…"
Thursday
Blake Reid commented on Blake Reid's blog post Managing Mold & Humidity (in Hawaii)
"Thank you very much! They're actually the same, though - the one with the dehu cover photo has…"
Thursday
John Proctor commented on Blake Reid's blog post Managing Mold & Humidity (in Hawaii)
"Nice post -- much better than the one that only showed the dehumidifier."
Thursday
Brett Little updated an event
Thumbnail

Full Circle Urban Forestry: Introducing Urban Wood Opportunities - Free CE Webinar at Webinar Online

December 5, 2018 from 12pm to 1:15pm
Many common urban tree removal practices in the United States view felled urban trees as costly…See More
Thursday
Brett Little replied to Brett Little's discussion Virtual CEU Tour of the Pembroke Passive Solar Zero Energy Ready Home
"You know utilities are pretty complex, especially in IL, however it looks like just about 6.8 cents…"
Thursday
yassin chahdi replied to Gary Wright's discussion Radiant Barrier Southeast
"It’s hard to choose on of these as most of the time the reviews and buying guides found on…"
Thursday
Bruce Fillmore replied to Mark Furst's discussion Bath fan weirdness
"In my opinion venting into any soffit is a bad idea, it usually requires a sharp bend to get into…"
Thursday
Tray Biasiolli replied to Mark Furst's discussion Bath fan weirdness
"I'd agree with Sean - we get wind effects regularly when measuring ventilation fan intake at…"
Thursday
Charles Buell replied to Mark Furst's discussion Bath fan weirdness
"You would have to test the vent at the inside at a location the same diameter as the outside…"
Thursday