It took me a while to figure out that a building is basically just a structural framework with control layers. Yeah, there's also electrical, plumbing, mechanical systems, and finishes, but the heart of a building is the stuff that holds it up and that moderates the flows of heat, air, and moisture between in and out.

One of those control layers is the air barrier. Of course, everyone knows now that a house can never be too tight (right?), so we want the air barrier to stop as much air flow across the building envelope as possible.

Many people believe that by putting house wrap on a building, you've got your air barrier taken care of. Although house wrap can qualify as an air barrier material, it usually doesn't behave as an air barrier when installed. Here's why:

  • All seams must be sealed. Builders usually do a decent job here. After installing the layers of housewrap, they go back and tape the seams.
  • Top and bottom edges must be sealed. This rarely happens, and there's a good reason why you shouldn't seal the bottom edge - You'll trap water inside when it gets behind the house wrap and can't drain out the bottom.
  • All the edges where it's cut at rough openings must be sealed. Doesn't happen. Also, not a good idea in places where water needs to be able to drain out.
  • Cladding contractors cut it with their box cutters to get it to lie flat. When house wrap goes through an inside corner, it often 'cuts the corner,' making it impossible to install siding without slitting it.
  • Innumerable tears, rips, and cuts allow air to move across it. They rarely get sealed before being covered with the cladding.

Because there are so many places that air can move across the house wrap, it doesn't really perform as an air barrier when installed. There is one type of air leakage that it does help reduce, however - infiltration, air moving into the house (as opposed to exfiltration, air moving out of the house).

When the air pressure outside the house is higher than the pressure inside, air wants to move to the inside. This pulls house wrap into the seams, gaps, and penetrations and inhibits the flow of air from outside to inside (infiltration). If the house pressure is higher than the outside pressure, on the other hand, the house wrap pushes away from the holes and air moves out of the house (exfiltration).

So, if house wrap isn't an air barrier, why do we use it?

House wrap's best use is to act as the drainage plane on a building. This control layer keeps liquid water that gets behind the cladding from wetting the building materials. Tar paper (also called building paper or felt) is the traditional material used for this application, but house wrap has is the dominant choice these days. It's kind of like Goretex for the house. It stops liquid water from going through, but it allows water vapor to pass so when the building materials do get wet, they can dry through the house wrap.

The more general term house wrap is weather resistive barrier (WRB), which implies that it's there to keep the weather out. It does that for rain that gets behind the cladding, but it won't resist air leakage due to wind, since wind puts a positive pressure on a house.

Bottom line: Don't think of house wrap as an air barrier. It's there to be the drainage plane.

 

This article has been cross-posted from the Energy Vanguard blog.

Views: 1024

Tags: air, barrier, house, resistive, weather, wrap

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Latest Activity

David Butler replied to Don Fugler's discussion joining ducts in the group HVAC
"Static pressure drop through a straight length of pipe is a function of friction rate, and friction…"
2 hours ago
Sean Wiens replied to Don Fugler's discussion joining ducts in the group HVAC
"Apparently the air passing over the PVC creates a strong static field that in turn impedes air flow."
2 hours ago
David Butler replied to Don Fugler's discussion joining ducts in the group HVAC
"Why would you think PVC has high resistance?"
2 hours ago
Sean Wiens replied to Don Fugler's discussion joining ducts in the group HVAC
"Thanks David - I was going to look at PVC for the HRV but was cautioned against it, not because of…"
2 hours ago
David Butler replied to Don Fugler's discussion joining ducts in the group HVAC
"Great post, Sean. I agree that screws are wise when joining metal ducts, but its also true that…"
3 hours ago
David Butler posted a discussion

Welcome Home Performance Forum Members (formerly RESNET BPI - Energy Audit and Home Performance)

Last month the Home Performance Forum merged with Home Energy Pros, now under the Home Performance…See More
4 hours ago
Sean Wiens replied to Don Fugler's discussion joining ducts in the group HVAC
"Various studies have indicated very little air flow along surface of duct (for ventilation - have…"
5 hours ago
Dara Bowser replied to Don Fugler's discussion joining ducts in the group HVAC
"Hi Don. We have never considered screws as impeding airflow, but I can see how in some ducts (e.g.…"
5 hours ago