A blower door measures how tight a house is

Air sealing done as part of the install, and after hacking holes into the house (and sealing others), total leakage only increased by 65 CFM50.  Still a B-ring house.

---------------------------------------------

I got a call from the east side of Hawaii, so I did what I always do.  I tested the house and collected some data.  The testing is important - no matter how well we think we know our houses, they can surprise us.  Without testing, it'd be like looking at someone and guessing if they have high blood pressure.  Sometimes it's obvious, but mostly it isn't.  I play small games with myself and try to guess how a house will behave before I test it.  I usually lose.

The blower door helps figure out why a house has a problem.  In this case we found consistently high humidity levels, coupled with a tight building envelope.  Because of the design of the house, it couldn't ventilate the moisture away at all.

HOBO data loggera Data logger takes snapshots of humidity levels


The building tightness was actually helpful; if the house were built today, it would be 25% better than Hawaii's Energy Code minimum for airtightness.  That meant that the environment could be more controlled, and a ducted dehumidifier would work.

Ultra-Aire 120H dehumidifier

Hanging the unit saved valuable floor space

DEH3000

The control is a "dehumidistat"

MERV 13 filter

A nice fat MERV 13 filter

This house doesn't have air conditioning, so it doesn't have a duct system either.  That can be an advantage, because a dedicated purpose-built duct system can be right-sized to match the unit.  As it's built, its joints are sealed and while you're at it, it'd be a good time to air seal the house too.  That helps keep the drier air from escaping as quickly.

ceiling registerCeiling diffusers are installed in the closets, so dry air doesn't blow directly on people. closets are also mold-prone areas.

ductwork

The joints on the ductwork should be sealed, otherwise, the air you want to keep in the house is squeezed out through the joints.

air sealing

these are electrician's holes, all sealed up with blobs of expanding foam. air sealing helps to keep conditioned air inside the house.

crawlspace hawaii

the crawlspace was air sealed too - there was plenty of air leakage around plumbing drains in particular

Once the unit is installed, and everything's attached, it's tempting to think that it'll work.  Why wouldn't it?  There are lots of potential reasons:

  • faulty equipment
  • shipping damage (the unit came from Wisconsin)
  • missed ductwork connections
  • install errors
  • control wiring mistakes
  • house alterations
  • etc.

So many things can go wrong that "commissioning" a system is crucial.  As part of a startup procedure, I take measurements.  I re-do the blower door test, because in this case seven large holes were cut in the building envelope and that could make the house leakier, which isn't helpful.  It's good to make sure all the new holes are sealed as best as possible.  I also measure the pressure in the ductwork, because in the instructions for the dehumidifier there's a table that tells you how the unit's performing.

static pressure

0.11 inches water column, correlates to about 310 cubic feet of air per minute

Ultra-Aire 120H dehumidifier Hawaii

from the instructions. always read the instructions.

But if you really want to make sure it's working, and not just hope it's working, you need a good amount of data.  I left my data logger behind to see what happened, and we learned a useful thing: in 18 hours, it's possible to reduce the humidity in the house by 20 percentage points.

relative humidity graphIn about 18 hours the house went from 85% RH to about 65% RH

Did I mention that this house is off-grid?  I got a call from the homeowner that the battery bank was drained and the generator didn't kick on.  Here's the same graph as above, just for a slightly longer time period.  You can see the humidity climb (when we experienced the power interruption), how quickly it climbed, and how quickly the unit drew the humidity level back down when the power came back on.

relative humidity graph 2 with power interruption

On the right side of the graph, we can see the dehumidifier "stuttering" as power came & went. once it was lost completely, the smooth part of the graph shows the steady rise of the humidity level, and then the sharp drop-off shows rapid drying.


That was a good thing to learn - the generator was offline!  It had never been an issue before, but because an 'ohana will be added, it became clear that more solar generation will be needed.

Mold needs certain conditions to grow, and one of them is a moist environment.  You could kill the mold, but if you don't change the conditions it'll just come back.  A drier (but not too dry) home is healthier.  If you're tired of moldy closets, or your child sneezes a lot, or your furniture is moving, get in touch.  We'll figure out what will work for you.

The data will tell us.

Previous blogs:

You Need a Bigly Dehumidifier part 1

You Need a Bigly Dehumidifier part 2

Staying Dry on Waimea's Wet Side

"Before" Pictures:

mold couch

moldy furniture

 

mold cabinet

some building products are more moisture-sensitive, like this kitchen cabinet

 

condensation

I mean, you can SEE the humidity. It's RIGHT THERE!

wood movement

the humidity was so high it split the furniture apart

dpcalc results

under the house's normal conditions, mold was guaranteed.

link to blog here:

https://terrawatthome.com/blog/managing-mold-and-humidity

Views: 45

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Blake Reid on Thursday

Thank you very much!

They're actually the same, though - the one with the dehu cover photo has a link that sends you to this very same blog, on my website.

Comment by John Proctor on Thursday

Nice post -- much better than the one that only showed the dehumidifier.

Forum Discussions

Blower door test for small apartment building

Started by Jerry Needham in General Forum. Last reply by John White on Friday. 9 Replies

ENERGY STAR Version 3

Started by Allison A. Bailes III in General Forum. Last reply by Franco Oyuela on Thursday. 9 Replies

Radiant Barrier Southeast

Started by Gary Wright in Best Practices. Last reply by yassin chahdi on Thursday. 6 Replies

Latest Activity

Brett Little posted a discussion

How to become a Certified GreenHome Professional - Free Webinar!

The Certified GreenHome Professional (CGHP) training is a way to learn about the basics of…See More
15 hours ago
Corbett Lunsford's video was featured

Testing Air Quality with Your Nose: Control Your HOMEChem

Charlie Weschler sits down with Grace and Corbett and gives fascinating examples of the complexity of indoor air chemistry. He is an air quality legend, a professor on three continents, and a super nice guy.
Friday
Profile Iconwallace van, Tony kroos and Sunmar Construction, Inc joined Home Energy Pros Forum
Friday
John White replied to Jerry Needham's discussion Blower door test for small apartment building
"Well, I think it completely depends on the purpose and requirement of the test. Testing one unit in…"
Friday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"I can use my Duct Blaster on any house that I expect to be less than 1300 CFM through the…"
Friday
Sean Lintow Sr replied to Jerry Needham's discussion Blower door test for small apartment building
"FYI, he is in Illinois where code is 5 (well up until March as noted when it drops to 4)  Heh…"
Friday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"Here are two pictures of the duct blaster fan as a blower door.  1 in a door and 1 in a…"
Thursday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"What standard are you testing to? Energy Star requires 5 ACH @ 50.   Code is 3.0 etc…"
Thursday
John Nicholas replied to Jerry Needham's discussion Blower door test for small apartment building
"What standard are you testing to? Energy Star requires 5 ACH @ 50.   Code is 3.0 etc…"
Thursday
Franco Oyuela replied to Allison A. Bailes III's discussion ENERGY STAR Version 3
"The ENERGY STARnew homes program has been around since the mid-1990s and is currently undergoing…"
Thursday
Blake Reid commented on Blake Reid's blog post Managing Mold & Humidity (in Hawaii)
"Thank you very much! They're actually the same, though - the one with the dehu cover photo has…"
Thursday
John Proctor commented on Blake Reid's blog post Managing Mold & Humidity (in Hawaii)
"Nice post -- much better than the one that only showed the dehumidifier."
Thursday
Brett Little updated an event
Thumbnail

Full Circle Urban Forestry: Introducing Urban Wood Opportunities - Free CE Webinar at Webinar Online

December 5, 2018 from 12pm to 1:15pm
Many common urban tree removal practices in the United States view felled urban trees as costly…See More
Thursday
Brett Little replied to Brett Little's discussion Virtual CEU Tour of the Pembroke Passive Solar Zero Energy Ready Home
"You know utilities are pretty complex, especially in IL, however it looks like just about 6.8 cents…"
Thursday
yassin chahdi replied to Gary Wright's discussion Radiant Barrier Southeast
"It’s hard to choose on of these as most of the time the reviews and buying guides found on…"
Thursday
Bruce Fillmore replied to Mark Furst's discussion Bath fan weirdness
"In my opinion venting into any soffit is a bad idea, it usually requires a sharp bend to get into…"
Thursday
Tray Biasiolli replied to Mark Furst's discussion Bath fan weirdness
"I'd agree with Sean - we get wind effects regularly when measuring ventilation fan intake at…"
Thursday
Charles Buell replied to Mark Furst's discussion Bath fan weirdness
"You would have to test the vent at the inside at a location the same diameter as the outside…"
Thursday
Blake Reid's blog post was featured

Managing Mold & Humidity (in Hawaii)

A blower door measures how tight a house isAir sealing done as part of the install, and after…See More
Thursday
John White replied to Cameron Home Insulation's discussion Why is Air Sealing Important?
"Most attics have insulation which helps reduce heat loss. But it won't stop the air flow.…"
Wednesday

Photos

  • Add Photos
  • View All

© 2018   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service