I run an energy program in the mountains of Colorado. We have a lot of homes without existing duct work and older style wall-mounted furnaces. I've been looking for a decent upgrade choice for my clients - so far Rinnai seems to be the brand of choice for most heating contractors.  Problem is they have an AFUE of only .82 at the max, so don't qualify for high-efficiency furnace rebates through our program.  

I recently discovered the Energy Saver 90 Plus from Empire Heating, a direct-vent wall mounted unit with an AFUE of .90.  I haven't been able to find any good information about the reliability and quality of these units, and I am distrustful of any company that manufactures ventless heaters, as Empire does.

Here is a link to the product I am referring to: http://www.empirezoneheat.com/ehs/index.php?view=ultrasaver-high-ef...

Generally speaking, what other options would be suitable to improve health and safety, as well as efficiency, for homes w/out duct runs?  I am talking affordable options as our community generally can't afford big expensive upgrades.  Pellet and wood stoves are also options but I'd prefer to hear about more natural gas options.

Thanks in advance!

Views: 5475

Tags: .90, AFUE, Direct, Empire, Equipment, Heating, Mount, Vent, Wall

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Bob Blanchette on March 20, 2014 at 7:43pm

Don't forget you have to deal with condensate removal on a 90% heater. Could be an issue for retrofit installations.

Comment by Cameron Millard on March 20, 2014 at 11:21am

Bob, we administer rebate funds to help people overcome payback costs for upgrades.  Agreed that 10% isn't that big of a difference; hence my dilema in supporting something like this.  I have given out rebate funds for 80% AFUE wall-mount replacements in the case of dangerous situations (replacing a ventless heater in a home, for example); I'm thinking the 90% would be a better justification for efficiency funds but without good practical experience with this particular product I am hesitant.  

Comment by Bob Blanchette on March 18, 2014 at 10:10pm

I replaced my own 80% with a 90% furnace last fall, made no noticeable difference in the gas bill. The payback time for going from 80% to 90% just isn't there unless you can buy the 90% for cheap.

Comment by Cameron Millard on March 18, 2014 at 3:30pm

Bob, price point is similar to a small furnace but without installation costs associated with duct runs.  I like your idea of installing a small furnace with registers off the plenum feeding several rooms; my building science mentor did something like that at his home and it worked out pretty well.  However, I do see demand here for wall-mounted furnaces.  We have an old housing stock (1880's-1950's), lots of small homes without much room for a conventional furnace.  Wall-mounted units like those made by Rinnai are quite popular and are often combined with small electrical heaters dispersed throughout the home.

Also, these do plug in so I'm not sure they work in a power outage?

Norman, thanks for chiming in about Empire products.  I just got word that some of our Colorado weatherization agencies will install wall mounted units; I think the jump from an 80 AFUE to a 90 would be a great gain for efficiency in the right situations.  The 90 Plus from Empire does require a condensate line w/either a pump or gravity feed into an appropriate drain; this complicates things when the location is not right and the home is on a slab, for example.

Comment by Norman Bair on March 18, 2014 at 1:18pm

Wisconsin's weatherization program replaces space heaters infrequently.  So I am interested in how well these perform. 

Our 1900+ Ft2 condo uses the 90% Empire Mantis fireplace for heat.  It was replaced on warranty after three years.  The replacement has worked for three additional winters.  The blower fan is very noisy.  Although it tests at 90% with a combustion analyzer, this must be discounted for the condensate that is pumped to a tray above the firebox and evaporated into the condo.  I clean the stainless steel tray with baking soda twice a year.  The original fireplace had the stainless steel tray eaten through at the welds and the inducer fan motor failed.  It gives out great heat.

Comment by Bob Blanchette on March 15, 2014 at 11:09am

There isn't much demand for these. Wall heaters are purchased due to low cost, most will spring for central systems before they will pay to upgrade to a 90% unit. Others buy wall units because they will work in power outages, but the 90% defeats this also. Other than getting rebate money, there is no reason to sell this product.

How does the price point of this product compare to a small 90% furnace? Frame in a base/closet for the furnace and use bottom for return/top for supply. Centrally locate furnace in house and have registers come right of the plenum to feed several rooms at once.

Forum Discussions

Speed Tips For Duct Airtightness Testing?

Started by Brendan Reid in General Forum. Last reply by David Butler 1 hour ago. 1 Reply

What made this chimney fall down?

Started by Eric Kjelshus in General Forum. Last reply by Eric Kjelshus on Tuesday. 7 Replies

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by Dave Taylor Nov 11. 61 Replies

Manual J (SD) for custom, luxury homes

Started by Dav Camras in HVAC. Last reply by Dav Camras Nov 10. 3 Replies

Quantitative methods for residential zoning

Started by Brett in HVAC. Last reply by David Butler Nov 9. 1 Reply

Latest Activity

David Butler replied to Brendan Reid's discussion Speed Tips For Duct Airtightness Testing?
"The Home Performance Forum archives include a number of discussions on various methods for sealing…"
1 hour ago
Brendan Reid posted a discussion

Speed Tips For Duct Airtightness Testing?

Anyone like to share their favorite ways to speed up duct airtightness ("Ductblaster") tests?I'm…See More
2 hours ago
Don Fugler added a discussion to the group HVAC
Thumbnail

joining ducts

A question came up on exhaust duct connections. I have always considered screws necessary for…See More
3 hours ago
Don Fugler joined Allison A. Bailes III's group
Thumbnail

HVAC

HVAC design, Manuals J, S, T, & D, Duct leakage, Air flow, ENERGY STAR new home requirements,…See More
3 hours ago
Profile IconSonny Roncancio and Chester Energy & Policy joined Home Energy Pros Forum
yesterday
Ryan Moore updated an event
Thumbnail

LEED for Homes Green Rater Training at Fort Collins, CO

December 7, 2017 to December 8, 2017
Green Insight will host this 2-day training in Fort Collins, CO December 7-8,…See More
yesterday
Rodney Bailey liked Rodney Bailey's discussion Energy audit equipment for sale.
yesterday
tedkidd liked Mike Rogers's blog post Focusing on payback to motivate customers?
Thursday

Photos

  • Add Photos
  • View All

© 2017   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service