Christopher Morin's Blog – August 2014 Archive (3)

Top 5 Changes to ACCA Manual S

      As I had brought up years ago, ACCA's Manual S was in dire need of an update.  Written in 1995, Manual S Residential Equipment Selection was passed by with huge technical and efficiency strides within the…

Continue

Added by Christopher Morin on August 27, 2014 at 8:30pm — 1 Comment

UPDATED: Big Changes for Duct Testing in MA

   If you have not been asked to complete a duct test by your local Massachusetts Inspector, it is just a matter of time before you are surprised by this stringent/updated code requirement.  Despite some push-back from Contractors  and Inspectors, all of MA is required to test new or altered duct systems.  All of MA adopted the 2012 International Energy…

Continue

Added by Christopher Morin on August 17, 2014 at 7:59pm — 9 Comments

No Bubbles, No Troubles!

Or is there? This saying is an old adage in our industry to let the technician know that the refirgerant charge is "all set". You see, there must be a steady stream of liquid to the metering device for it to function properly. For sake of conversation, let's use the TXV. In order for most TXV's to throttle and correctly maintain the desired Superheat, there must be a minimum of 2F of subcooled liquid at the valve (not where it is measured, near the condenser). If the liquid were to flash off… Continue

Added by Christopher Morin on August 12, 2014 at 4:19pm — No Comments

Forum Discussions

Home Energy Pros and #MeToo

Started by Mike Rogers in General Forum. Last reply by Diane Chojnowski 2 hours ago. 1 Reply

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler 21 hours ago. 34 Replies

Psychrometric Chart Training

Started by John Krochmalny in Training. Last reply by Mahendra Shah on Friday. 1 Reply

Latest Activity

Blake Shurtz posted a discussion

Replacement for Energy Conservatory Flow-blaster

It's too bad that the flow-blaster is no longer being produced or technically supported. Does…See More
7 minutes ago
Diane Chojnowski replied to Mike Rogers's discussion Home Energy Pros and #MeToo
"Mike, thanks so much for supporting women and the #MeToo campaign. Women everywhere  have…"
2 hours ago
Profile IconBrian Cizmar, Charles Allen, Charles Buell and 1 more joined Home Energy Pros Forum
2 hours ago
Mike Rogers posted a discussion

Home Energy Pros and #MeToo

If it doesn't seem obvious why a discussion of …See More
6 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"Sean Lintow proposed rails and clips (re: first comment in this discussion), but in the context of…"
21 hours ago
Brad Cook replied to David Butler's discussion How would you insulate this roof?
"I missed where the suggestion for rails came in. The plywood would not need any rails. 4+ inches is…"
yesterday
David Butler replied to David Butler's discussion How would you insulate this roof?
"I'm a little confused about the necessity and purpose of using support rails if working on…"
yesterday
David Butler replied to David Butler's discussion How would you insulate this roof?
"If you insulate master bedroom and family room from below, you definitely need more R-value than…"
yesterday