Blower Door Question

Started this discussion. Last reply by j. west Dec 18, 2014. 15 Replies

We are having a friendly (so far) discussion here on the following. When you initially run your blower door to -50pa all the holes, cracks, bypasses and any thing else connected to the outside is…Continue

We are past the point of who's fault is it....

Started this discussion. Last reply by Eric Kjelshus Jan 13, 2014. 1 Reply

A client had a new double wide set (27x56) in1997 a couple years later had an addition (27x20) to the west side with 27x20 attached garage to that addition, the general contractor tells the client a…Continue

Implementing ASHRAE 62.2

Started this discussion. Last reply by Thom Knoll Oct 19, 2013. 14 Replies

I work with a C.A.O. here in Ohio under the W.A.P. now that D.O.E. requires implementing ASHRAE 62.2  2010 as of PY 13 and 62.2  2013 in PY 14 my concern is accomplishing this correctly.The…Continue

 

billy g pinnick jr's Page

Profile Information

Company
community action org. delaware,madison,union,logan,champaign,shelby co.s
Professional Certification
BPI Building Analyst,DOE/BPI Quality Control Inspector, State of Ohio Wx Inspector, Warm Choice Inspector

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 5:17pm on October 5, 2013, Diane Chojnowski said…

Hi Billy,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Forum Discussions

Psychrometric Chart Training

Started by John Krochmalny in Training 5 hours ago. 0 Replies

Too many Heat Pump Water Heaters in a basement?

Started by Brad Cook in General Forum. Last reply by Michael Duclos 10 hours ago. 10 Replies

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler on Monday. 2 Replies

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco on Monday. 1 Reply

Latest Activity

B Eric Bell liked Bob Krell's group Healthy Indoors (IAQ)
2 hours ago
John Krochmalny posted a discussion

Psychrometric Chart Training

Looking through the various areas of this site, I didn't see too much information or training on…See More
5 hours ago
Profile IconMike Malek, Avery T. Phillips and Sarah Burger joined Home Energy Pros Forum
6 hours ago
Dannie Jackson's blog post was featured

Core Heat And Other Concepts

  In some places the use of solar heated liquids from hot water solar panels are used to provide…See More
10 hours ago
Michael Duclos replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"I’ve been looking into Sanden for a multi-family PH near Laconia, NH, ASHRAE 99.6% temp is…"
10 hours ago
Profile IconTroy Spindler, Mike Berg, Andrew McDowell and 4 more joined Home Energy Pros Forum
yesterday
David Butler replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"theoretically, let's say you perfectly isolate the HPWH from a heat source. The HPWH's…"
Monday
David Butler replied to David Butler's discussion How would you insulate this roof?
"Interesting idea. Commercial roof on a slope! Typical density for roofing spray foam is 2.5 to 3.0…"
Monday