Two-stage furnace, control at furnace or thermostat?

Started this discussion. Last reply by Rob Jan 23, 2018. 11 Replies

Got called in recently to address thermostat and comfort issues for a local builder we work with. In reconfiguring the thermostat (…Continue

 

Tray Biasiolli's Page

Latest Activity

Tray Biasiolli replied to Mark Furst's discussion Bath fan weirdness
"I'd agree with Sean - we get wind effects regularly when measuring ventilation fan intake at the outdoor hood. And there's a notable difference if the capture hood is flush with the wall (eg around foundation wall) or if there are gaps,…"
Oct 11, 2018
Rob replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"I installed/configured a couple Honeywell VisionPro 8k models recently in a commercial facility. It has governing ability for 4 stages of heat and 2 of cool. It triggers out from 1st stage when sensing 90% capacity of the furnace.  "
Jan 23, 2018
Mick Lane replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"I was playing with a 2 stage carrier furnace last week.  The staging is not bad on the condensing boilers.  They camp out at low fire until the return air temp drops or they get past 5 minutes of run time.  I am fine with them doing…"
Jan 23, 2018
John Proctor replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"Ted -- The startup losses on modern furnaces are much smaller than the old days. I would suggest a modification to your statement to: "if the ducts are normal and in unconditioned space then the losses exceed the gains from long run…"
Jan 22, 2018
Robert Zockoff liked Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
Jan 18, 2018
tedkidd replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"We use reverse staging on ecobee. Generally, the best comfort, energy savings, iaq, etc are achieved by doing what you can to avoid having the equipment ever shut off. We suspect among other things, start/stop losses are significant. If the…"
Jan 11, 2018
Tray Biasiolli replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"Thanks, John. The HVAC installers have actually responded to incentives and moved ducts within the building envelope on the vast majority of the furnaces we see, so losses to unconditioned space are less of a concern for us. Thanks for bringing up…"
Jan 5, 2018
David Butler replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"@Tray, the staging logic is described on pg 85 of the furnace installation manual. In particular, here's what it says: "This furnace can operate as a two--stage furnace with a single-stage thermostat because the furnace control CPU…"
Jan 5, 2018
Eric Kjelshus replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"Set up for 1st stage to run at highest eff.   With my set up will run on 1st stage 93% of time.   Use a high end flue gas meter and set up for max eff.   "
Jan 5, 2018
Tray Biasiolli replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"Thanks for the quick feedback, David. I did find the furnace install manual earlier; there's no detail (that I was able to find) on staging logic or adjusting staging timing. Glad to understand the typical thermostat staging in a bit more…"
Jan 4, 2018
John Proctor replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"I hate to be the one to bring this up, but two stage furnaces are quite capable of having lower installed efficiency than single stage furnaces with the same max input. This comes from two sources: 1) the fuel air mixture on low fire often has too…"
Jan 4, 2018
Kent Browning replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"David's comment is spot on. I would always prefer thermostat staging control over furnace staging control. (I am assuming the thermostat is making and breaking the control call for heating - not communicating the temperature back to the furnace…"
Jan 4, 2018
Diane Chojnowski left a comment for Tray Biasiolli
"Hi Tray, Welcome to Home Energy Pros Forum. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for…"
Jan 4, 2018
David Butler replied to Tray Biasiolli's discussion Two-stage furnace, control at furnace or thermostat?
"I'm not sure about the Ecobee Smart Si (I couldn't immediately find the install manual) but this FAQ (http://bit.ly/2Cf2UsR) describes Ecobee's staging logic -- it's selectable based on either elapsed time or temperature…"
Jan 2, 2018
Tray Biasiolli posted a discussion

Two-stage furnace, control at furnace or thermostat?

Got called in recently to address thermostat and comfort issues for a local builder we work with. In reconfiguring the thermostat (Ecobee Smart Si), I noticed that it was wired up as a single stage for heating, although the furnace (Carrier 59TP6) is a two-stage model - that is, furnace staging decisions…See More
Jan 2, 2018
Tray Biasiolli is now a member of Home Energy Pros Forum
Jan 2, 2018

Profile Information

Company
Think Little
Role in Home Performance Marketplace
Building energy modeler, Energy auditor / assessor / analyst
Professional Certification
BPI, HERS Rater
Website URL
http://www.think-little.com

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 8:56am on January 4, 2018, Diane Chojnowski said…

Hi Tray,

Welcome to Home Energy Pros Forum. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo.

Thanks!
Diane, HEP Forum Moderator

 
 
 

Forum Discussions

high rise humidity

Started by Steve Nations in HVAC 9 hours ago. 0 Replies

Ducted mini split vs ceiling cassettes?

Started by Alan Lehman in General Forum. Last reply by Alan Lehman 11 hours ago. 5 Replies

70 unit building rehab

Started by Jerry Needham in Multifamily. Last reply by Jacob Corvidae 15 hours ago. 3 Replies

Indoor Air Quality Monitors and Meters

Started by Rob Madden in General Forum. Last reply by Al Tibbs on Tuesday. 13 Replies

Latest Activity

Steve Nations posted a discussion

high rise humidity

I have a friend/client with dry conditions in his condo. He's on the top floor of a 17-story…See More
9 hours ago
Profile IconAidan Conway and Todd Kistler joined Home Energy Pros Forum
10 hours ago
Alan Lehman replied to Alan Lehman's discussion Ducted mini split vs ceiling cassettes?
"Thanks for that info. I am a novice with Mini Splits so this is great info. I will shop that unit…"
11 hours ago
David R Koons replied to RANDY's discussion starting up audit company in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Shared with you within this forum"
12 hours ago
Michael Dunseith posted photos
13 hours ago
David Butler replied to Alan Lehman's discussion Ducted mini split vs ceiling cassettes?
"@Alan, I'm confused... three comments: a) Why would sound transmission be an issue for the air…"
13 hours ago
Todd Kistler added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Energy Auditor Equipment For Sale

***Complete Energy Auditor Set Up***Excellent Condition***Minneapolis Blower Door (Complete with…See More
15 hours ago
Jacob Corvidae replied to Jerry Needham's discussion 70 unit building rehab
"With less than $1,000 / unit and comfort as the primary driver, air-sealing and select insulation…"
15 hours ago

© 2019   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service