TJ Alexander
  • Sunapee, NH
  • United States
Share on Facebook Share

TJ Alexander's Friends

  • Marg properties

TJ Alexander's Discussions

So many homes have poorly installed fiberglass insulation. Have you been successful with a retrofit dense pack cellulose?

Started this discussion. Last reply by James P. Weingardt Jul 5, 2014. 5 Replies

Doing testing of existing homes it is typical to see mottled patterns of surface temperatures with the FLIR Infrared Thermal Imager during Blower Door Testing.  Part of the problem is air sealing and…Continue

 

TJ Alexander's Page

Profile Information

Company
Thermo Building Services LLC
Professional Certification
BPI Building Analyst
Professional Interests
Energy Auditing and problem solving in existing buildings as well as energy efficiency.

I am also involved in energy saving retrofits as well as heating and HVAC system upgrades and alternative energy sources. Keeping up with regular training on the best use of materials and design of mechanical systems to get the best efficiency to cost ratio for the client.
Website URL
http://thermobuildingservices.com

Passive House interest

We have several passive house inspired projects in the planning stage in New Hampshire.

 As usual with some folks in the business, I am going to build my own net zero home. That way I don't have to sell or compromise on the important points and construction methods with folks who think they have the answer or don't think the details are important.

In doing quality control work in new construction with the established conventional builders, the passive house influences and advice seem to be ignored and disparaged.

There are buildings being constructed that offer the promise of a healthy house with low energy use and reasonably priced, durable construction.

TJ Alexander's Blog

So many homes have fiberglass insulation that is poorly installed in New Hampshire and elsewhere

Posted on June 12, 2014 at 4:31pm 0 Comments

Doing testing of existing homes it is typical to see mottled patterns of surface temperatures with the FLIR Infrared Thermal Imager during Blower Door Testing.  

Part of the problem is air sealing and the other part of the problem is poorly installed fiberglass insulation.

This is not a rant against fiberglass insulation (I am a fan of both Rock Wool/Roxul and dense packed cellulose) for retrofit projects.  Fiberglass batt or blown insulation can perform fine, if it is…

Continue

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 11:04pm on February 15, 2012, Diane Chojnowski said…

Hi TJ,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Forum Discussions

Psychrometric Chart Training

Started by John Krochmalny in Training 13 hours ago. 0 Replies

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler on Monday. 2 Replies

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco on Monday. 1 Reply

Latest Activity

David Butler replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"Hi Mike, it's good to get some feedback from the field, and thanks for confirming Gen 3 is now…"
2 hours ago
B Eric Bell liked Bob Krell's group Healthy Indoors (IAQ)
11 hours ago
John Krochmalny posted a discussion

Psychrometric Chart Training

Looking through the various areas of this site, I didn't see too much information or training on…See More
13 hours ago
Profile IconMike Malek, Avery T. Phillips and Sarah Burger joined Home Energy Pros Forum
14 hours ago
Dannie Jackson's blog post was featured

Core Heat And Other Concepts

  In some places the use of solar heated liquids from hot water solar panels are used to provide…See More
19 hours ago
Michael Duclos replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"I’ve been looking into Sanden for a multi-family PH near Laconia, NH, ASHRAE 99.6% temp is…"
19 hours ago
Profile IconTroy Spindler, Mike Berg, Andrew McDowell and 4 more joined Home Energy Pros Forum
yesterday
David Butler replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"theoretically, let's say you perfectly isolate the HPWH from a heat source. The HPWH's…"
Monday

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service