Mold on a ceiling diffuser

Started this discussion. Last reply by John Nicholas Aug 20, 2015. 3 Replies

I have a client that called today and said they had a mold like material on the ceiling next to a supply air outlet in a bedroom. We installed a geothermal split system about 6 years ago in the well…Continue

 

Stephen Wierzbicki's Page

Latest Activity

Stephen Wierzbicki added a discussion to the group Job Board
Thumbnail

Buiding Analyst in Hartfrd Connecticut Area.

We are in need of a Building Analyst and Envelope Professional to perform audits for the Utility Company HES program. The successful candidate shall be able to perform energy audits, perform CAZ testing, blower door, duct blaster tests, true flow plate tests, perform on the spot upgrades and repairs, work well with our clients and advise on energy efficiency improvements. Aero Seal duct sealing expierence is a plus. If this sounds like a good fit for you please send your resume to…See More
Apr 21, 2016
Stephen Wierzbicki joined Diane Chojnowski's group
Thumbnail

Job Board

This group is for posting jobs related to all aspects of the home performance industry including energy auditors, technicians, and weatherization pros.See More
Apr 21, 2016
John Nicholas replied to Stephen Wierzbicki's discussion Mold on a ceiling diffuser
"Stephen,    The mold is in one place.  That means moisture is in that place.  Until you have discovered why the moisture is present where the mold is, you are not any closer to a solution. Yes,  You need to fix the entrance…"
Aug 20, 2015
Stephen Wierzbicki replied to Quinn Korzeniecki's discussion Let's Play Stump the Chump! What's Wrong with this Picture? in the group Building Performance Institute (BPI)
"I would guess there is no wall insulation on the upper portion of the wall and they have air conditioning units operating."
Aug 20, 2015
Stephen Wierzbicki joined Building Performance Institute's group
Thumbnail

Building Performance Institute (BPI)

BPI is the nation's premier standards development, quality assurance and credentialing organization for residential energy efficiency retrofit work.See More
Aug 20, 2015
Stephen Wierzbicki replied to Stephen Wierzbicki's discussion Mold on a ceiling diffuser
"Hi Hal, I appreciate the reply. This system is in an encapsulated attic with R-38 roof 2 part foam, the duct is insulated with an R-6 just as an added precaution. The ducts are all metal with 6 feet of R-6 flex at each air outlet and return air…"
Aug 18, 2015
Hal Skinner replied to Stephen Wierzbicki's discussion Mold on a ceiling diffuser
"So I understand this correctly, AC unit, and ducts in the attic.  CDan I assume METAL ducts?  This sounds like the same problem we have ran into with commercial units in areas of high humidity in CA.   Your R- insulation works against…"
Aug 18, 2015
Stephen Wierzbicki's discussion was featured

Mold on a ceiling diffuser

I have a client that called today and said they had a mold like material on the ceiling next to a supply air outlet in a bedroom. We installed a geothermal split system about 6 years ago in the well built home with an attic air handler. The attic is encapsulated with R38 two part foam on the roof rafters, the duct work is sealed and insulated with R-6 insulation and passed all energy star HERS testing. We inspected the air handler which was clean, inspected the duct work in the attic which was…See More
Aug 17, 2015
Stephen Wierzbicki replied to Luis Hernandez's discussion Solar hot water exterior pipes insulation
"We use either 2 inch foam (armaflex) with the aluminum jacket already applied and we buy aluminum 90 fitting covers and use an aluminum butyl tape. If that is not available we use 2 inch fiberglass insulation and cover it with a PVC…"
Aug 15, 2015
Stephen Wierzbicki posted a discussion

Mold on a ceiling diffuser

I have a client that called today and said they had a mold like material on the ceiling next to a supply air outlet in a bedroom. We installed a geothermal split system about 6 years ago in the well built home with an attic air handler. The attic is encapsulated with R38 two part foam on the roof rafters, the duct work is sealed and insulated with R-6 insulation and passed all energy star HERS testing. We inspected the air handler which was clean, inspected the duct work in the attic which was…See More
Aug 14, 2015
Gregory Homan left a comment for Stephen Wierzbicki
"Hi Stephen, Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for…"
Feb 9, 2015
Stephen Wierzbicki is now a member of Home Energy Pros Forum
Feb 9, 2015

Profile Information

Company
Nutmeg Mechanical Services Inc.
Professional Certification
BPI
Professional Interests
Home Performance
Geothermal
Solar Thermal
Website URL
http://nutmegmechanical.com

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 4:14pm on February 9, 2015, Gregory Homan said…

Hi Stephen,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to add your profile photo and be sure to put your location on our Member Map!

Thanks!
Gregory, HEP Moderator

 
 
 

Forum Discussions

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler 19 hours ago. 15 Replies

Psychrometric Chart Training

Started by John Krochmalny in Training. Last reply by Mahendra Shah 22 hours ago. 1 Reply

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco on Monday. 1 Reply

Latest Activity

tedkidd replied to Bob Blanchette's discussion Tankless Water Heaters... has their time finally come?
"Yeah. Gas water…"
11 hours ago
Eric Kjelshus replied to Bob Blanchette's discussion Tankless Water Heaters... has their time finally come?
"With super cheap natural gas prices now, still worth going all electric?  Tankless needs a lot…"
12 hours ago
Stuart Langley liked Chris Clay's photo
17 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"Stuart, I wasn't considering the copula windows... yes, those would indeed need to be…"
19 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"Well, @David Butler, you have seen the property more accurately than I have, but my impression of…"
19 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"@ Stuart,I don't think there's any concern about impact of 4" build-up on elevation…"
20 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"So this building has a few issues with air leaks and air leaks have so much to do with discomfort…"
20 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"John Hatfield has the right idea here for a new roof deck. Polyiso boards always need a good stout…"
21 hours ago