Shannon Phillips
  • Los Angeles, CA
  • United States
Share on Facebook Share

Shannon Phillips's Groups

 

Shannon Phillips's Page

Profile Information

Company
We Green Inc.
Professional Certification
LEED AP, HERS, BPI Building Analyst, Envelope
Website URL
http://www.wegreeninc.com
Blog URL
http://www.wegreeninc.com/news
Twitter ID
https://twitter.com/wegreen1
Facebook Page
https://www.facebook.com/WeGreenInc
LinkedIn Profile
http://www.linkedin.com/profile/edit?trk=hb_tab_pro_top

Comment Wall (1 comment)

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

At 10:54am on November 11, 2012, Diane Chojnowski said…

Hi Shannon,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Latest Activity

Sean Lintow Sr replied to John Carton's discussion Insulation touches underside of roof in home with no soffit or soffit venting.
"Location, location, location In hot dry climates - not really an issue unless it gets damp (and yes…"
4 hours ago
Michael Schettine liked Michael Schettine's video
5 hours ago
Bradford E. White replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Agreed! True, if an open plan. Simple is best. But away spaces seem to be making a come-back. And…"
7 hours ago
Kurt Shafer replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Jerry, as an energy consultant I imagine you are well versed in solar systems. Have you seen how…"
7 hours ago
Scott Mills replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"I have found that ceiling fans are the simplest way to control room stratification "
8 hours ago
Matt Peiris replied to H.O. Electric's discussion Stop Drinking Bottled Water! in the group News & Announcements
"Well water consumers need to test their water every year. Elevated arsenic, nitrate levels or…"
9 hours ago
Kurt Shafer replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Jerry I don't have videos posted yet but I have some nice pictures from customers. See them…"
9 hours ago
Scott Mills is now a member of Home Energy Pros Forum
9 hours ago
Bradford E. White replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Qualified "It Depends" kind of answer. 1. Temperature Perception: There is an intangible…"
9 hours ago
John Carton posted a discussion

Insulation touches underside of roof in home with no soffit or soffit venting.

I performed an assessment for a recent home buyer and the home inspector they hired when they…See More
10 hours ago
Jerry Needham replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Kurt Thanks for the information on the whole house fan and the advise about leaving the fan on all…"
10 hours ago
James White replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"There is more than fan energy to be saved by setting fans to run on "auto". Most forced…"
10 hours ago
Kurt Shafer replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Jerry, I am a whole house fan expert but not an HVAC expert. However, I have no idea why any HVAC…"
10 hours ago
Jerry Needham replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Ken This is a great response.  Lots of arguments against leaving the fan on. THANKS"
10 hours ago
Luke Langhals replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"If an E/HRV system is installed in unison with the furnace ducting -- you might consider making the…"
10 hours ago
Ken Summers replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"At Comfort Institute we get asked this question all the time.  The argument for leaving the…"
10 hours ago
Allison A. Bailes III replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Jerry, as Chris Heenan said below, running the fan continuously will raise the indoor humidity in…"
10 hours ago
Chris Heenan replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"In regions with _high_ humidity, running the fan continuously will be put moisture that the…"
10 hours ago
Barbara Smith replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"Eliminating continuous furnace fan operation is #3 on list of top ways to cut energy use, in this…"
10 hours ago
tedkidd replied to Jerry Needham's discussion HVAC Question about running fan continuously Vs. setting on Auto so it runs when AC or Furnace runs
"There is no Pat answer. It depends. In a well performing home with proplerly sized equipment and…"
10 hours ago

Photos

  • Add Photos
  • View All

© 2018   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service