ZPD House

Targeted airsealing, series leakage testing, duct balancing, and blower door testing can be performed. The ZPD House can be projected onto a screen for larger audiences.

Views: 268

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Dale@EnergyWright on March 1, 2011 at 10:22pm
Thanks, Jack and Michael. That was the idea behind designing it.  Most of the folks we train are kinesthetic learners, they see a problem and go hands-on to fix the problem.  Pressure diagnostics is a little different, it requires folks to build a mental framework of a particular building's interactive pressures, determine the issues and solutions, fix it, then confirm it was corrected properly.  Not an easy task when much of the reconstruction work happens in your head.  We expect this pressure diagnostics simulator will provide the intuitive mental exercises needed to make for effective auditors and technicians in the field.
Comment by Jack Baikoff on March 1, 2011 at 7:00pm
This looks like a wonderful educational tool
Comment by Michael Dunseith on February 19, 2011 at 5:15pm
AWESOME Dale

Latest Activity

Dara Bowser replied to Don Fugler's discussion joining ducts in the group HVAC
"Good to hear you have clean dryer ducts Don. The dryer duct issues that we run into are…"
14 hours ago
Don Fugler replied to Don Fugler's discussion joining ducts in the group HVAC
"David, If the IMC mandates metal dryer duct and prohibits metal screws, they must be accepting…"
15 hours ago
David Butler replied to Don Fugler's discussion joining ducts in the group HVAC
"I never checked that before. Checking now... Section M1502.4.2 of the International Residential…"
15 hours ago
Joseph Frasier is now a member of Home Energy Pros Forum
15 hours ago
Don Fugler replied to Don Fugler's discussion joining ducts in the group HVAC
"Brendan, Thanks for that response. Because of your warning, I just went down to the basement and…"
19 hours ago
Brendan Reid replied to Don Fugler's discussion joining ducts in the group HVAC
"Hi Don, Summary: DRYER VENT: screws bad idea, possibly prohibited by code. METAL DUCT: must be…"
20 hours ago
Profile IconBrendan Reid and David Butler joined Allison A. Bailes III's group
Thumbnail

HVAC

HVAC design, Manuals J, S, T, & D, Duct leakage, Air flow, ENERGY STAR new home requirements,…See More
20 hours ago
Profile IconSean Wiens and David Butler joined Chris Laumer-Giddens's group
Thumbnail

Energy Efficient Design

Energy efficiency starts at the drafting table...How architects and designers can help buildings…See More