VISTA AC

Single AC unit serving 2-story 1,200 sq ft paint store show room. Done on a 103 degree day. Immediately dropped interior air temp 7 degrees. Next day, also 103 degrees. Manager called and said it was 12 degrees colder than before the RCC was applied to the AC unit.

Views: 61

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Hal Skinner on August 7, 2014 at 11:41pm

In most cases, water and a brush.  If the surface area is filthy, oily, greasey, what works best is liquid tide with bleach.  We will wet down the surface area, AC unit, metal roof etc, spray on liquid tide with bleach from a garden sprayer, scrub it, rinse it, let it dry.   100% environmentally friendly.  Once dry, spot prime any rust.  Spray or roller on the RCC.  Cooling effect is immediate.

Comment by Eric Kjelshus on August 7, 2014 at 9:35pm

what do you clean it with?  Most RTU are just nasty - grease from Kitchen to concrete  dust to road tar to bird dropping 

Comment by Hal Skinner on August 7, 2014 at 6:20pm

Our RCC is such a good sealant it is used as an encapsulant material for asbestos.  But, that had no bearing on this application.

 

I apologize for lack of good editing on here.  My vision is bad enough it is very difficult.

Comment by Hal Skinner on August 7, 2014 at 5:43pm

Hi Eric,

I did this one myself.  I cleaned it, masked off all the ID plates and stickers and painted on our RCC.  Nobody did anything with the outside air intake.

Our RCC has Solar Reflectivity of 0.83

                                 Emissivity of  0.90

Here is how that was explained to me by a couple of folks from energy labratories.

Using our numbers;  83% of the sun's heat energy is reflected away from the material.

This leaves 17% that actually enters the surface of the material.

Of THAT 17%, 90% of that is emitted back into the atmosphere.

Do the math and that leaves 1.7% that actually goes past  the RCC and enters the building.

 

If your numbers are referring to ther 'coloor spectrum, I will give an example of a white RCC does vs standard white paint.

@00,000+ sq ft metal building.  Egg processing pl;ant in Texas.  Metal roof was white from the factory (Baked enamel?)  Walls were a light yellowish tan from the factory.

First thing cpoated was the roof..  That immediately dropped the surface temperature from 196 degrees down

to 110 degrees.  It also dropped the attic air teperature by 60 degrees.  Iy was a 108 degree day.

The surface temperature of our RCC will alway be within 5 degrees of whatever the ambient air teperature is at that moment..

IT AINT PAINT!  :)

 

Comment by Eric Kjelshus on August 7, 2014 at 3:59pm

I have seen roof top units leak 45% on both supply and return.   I have see the slitter between supply and return just rot with leaking air- conditioned air hits hot air than rains.   Yours is more just color than sealing, black is 93% and white is 7% solar heat pick up.  How much of that is from closing the outside air off?

Latest Activity

Chris Dorsi posted an event
Thumbnail

2018 Habitat X Summer National Conference at Big Sky Montana

June 27, 2016 to June 29, 2016
The 2018 Habitat…See More
6 hours ago
Stuart Langley liked David Byrnes's blog post Strategies for Hiring and Interviewing for Home Performance Professionals
10 hours ago
Kevin Miller replied to Bob Krell's discussion What Do You Do When You Find Suspected Mold? in the group Healthy Indoors (IAQ)
"Visual inspection can only confirm the presence of mold, not the absence.   That said,…"
13 hours ago
Armand C Magnelli replied to Don Fugler's discussion joining ducts in the group HVAC
"I often suggest pop-rivets as an alternative to sheet metal screws for both clothes dryer duct work…"
13 hours ago
Kevin Miller replied to Bob Krell's discussion What Do You Do When You Find Suspected Mold? in the group Healthy Indoors (IAQ)
"Sampling would be primarily to verify 'Condition 1' or 'Normal Fungal Ecology'…"
13 hours ago
Daniel Cullen joined Building Performance Institute's group
Thumbnail

Building Performance Institute (BPI)

BPI is the nation's premier standards development, quality assurance and credentialing organization…See More
13 hours ago
Daniel Cullen replied to Bob Krell's discussion What Do You Do When You Find Suspected Mold? in the group Healthy Indoors (IAQ)
"Can anyone tell me exactly HOW mold sampling impacts the mold remediation process or protocol? Why…"
13 hours ago
Daniel Cullen joined Bob Krell's group
Thumbnail

Healthy Indoors (IAQ)

The Healthy Indoors group is focused on indoor air quality (IAQ), mold, moisture control, radon,…See More
13 hours ago

Photos

  • Add Photos
  • View All

© 2017   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service