The Pond Down Under

How many homeowners know what is going on in their crawspace?

I see a couple of problems with this one!

Views: 103

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Guy DuBois on January 20, 2012 at 7:58am

This is apparently spring fed water. Clear and clean looking. The sump pump is broken. I'm told that up until recently there was a family of skunks living in there. The fix would involve pumping the water out, jacking the beam back to level and shoring up those eroded columns after installing proper footers. Notice the waterlogged temporary 2x4. The sump discharge line goes to the front where the lot has plenty of negative grade. A proper drainage system could be installed that terminates downhill in the front yard. This means that the drain would have to pass under the foundation in the front. I'll have to check with an engineer to determine the correct way to address this breach below the foundation. 

Comment by Bob Blanchette on January 17, 2012 at 8:24pm

How are you gonna fix the pond?

Latest Activity

Dara Bowser replied to Don Fugler's discussion joining ducts in the group HVAC
"Good to hear you have clean dryer ducts Don. The dryer duct issues that we run into are…"
8 hours ago
Don Fugler replied to Don Fugler's discussion joining ducts in the group HVAC
"David, If the IMC mandates metal dryer duct and prohibits metal screws, they must be accepting…"
9 hours ago
David Butler replied to Don Fugler's discussion joining ducts in the group HVAC
"I never checked that before. Checking now... Section M1502.4.2 of the International Residential…"
9 hours ago
Joseph Frasier is now a member of Home Energy Pros Forum
9 hours ago
Don Fugler replied to Don Fugler's discussion joining ducts in the group HVAC
"Brendan, Thanks for that response. Because of your warning, I just went down to the basement and…"
13 hours ago
Brendan Reid replied to Don Fugler's discussion joining ducts in the group HVAC
"Hi Don, Summary: DRYER VENT: screws bad idea, possibly prohibited by code. METAL DUCT: must be…"
14 hours ago
Profile IconBrendan Reid and David Butler joined Allison A. Bailes III's group
Thumbnail

HVAC

HVAC design, Manuals J, S, T, & D, Duct leakage, Air flow, ENERGY STAR new home requirements,…See More
14 hours ago
Profile IconSean Wiens and David Butler joined Chris Laumer-Giddens's group
Thumbnail

Energy Efficient Design

Energy efficiency starts at the drafting table...How architects and designers can help buildings…See More