sealed soffits near fan exhaust

sealing some soffits to fix ice damming

Views: 769

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Adin Maynard on July 30, 2011 at 7:47am
Bryce, thanks for the comment. Yes the flat was fully airsealed and brought up to R-60 with cellulose.  Each standard chute vent was improved, as can be seen in far left bay in image above. The few soffits near the bath fan were sealed to prevent exhaust air from bring brought back into the attic.  THere was plenty of 'low/high' ventilation, so this approach was taken. 
This past winter was crazy for ice damming. As a result, for attic retrofits, we are careful to improve and maintain soffit vents whenever possible.
Comment by Bryce Cramer on July 29, 2011 at 1:52pm
Not sure if I understand how sealing the flow of air through the soffit will reduce ice damns. The better approach would be to stop the heat loss through the attic floor with a better insulation job. Then provide proper ventilation so that the roof deck remains cold and does not therefore melt snow that refreezes over a cold soffit. If the bathroom vent is just vented into the soffit area, I would think this would cause additional issues. The warm air (moist) air will hang inside the soffit area since the soffit is now sealed from the rest of the atiic....this should lead to moisture, mold and other problems in the roof deck above this soffit area.

Forum Discussions

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler yesterday. 2 Replies

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco yesterday. 1 Reply

Fixing a water heater?

Started by John Shillito in Best Practices. Last reply by Eric Kjelshus on Friday. 21 Replies

Latest Activity

Profile IconAvery T. Phillips, Sarah Burger, Troy Spindler and 2 more joined Home Energy Pros Forum
5 hours ago
David Butler replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"theoretically, let's say you perfectly isolate the HPWH from a heat source. The HPWH's…"
yesterday
David Butler replied to David Butler's discussion How would you insulate this roof?
"Interesting idea. Commercial roof on a slope! Typical density for roofing spray foam is 2.5 to 3.0…"
yesterday
Profile IconRandy Kinnison, Breanna Detwiler, Jeff Farlow and 7 more joined Home Energy Pros Forum
yesterday
Summer Redman added a discussion to the group Job Board
Thumbnail

Hiring 2 Training Specialists in Champaign-Urbana, Illinois

The Applied Research Institute (ARI) at the University of Illinois at Urbana-Champaign is seeking…See More
yesterday
Summer Redman joined Diane Chojnowski's group
Thumbnail

Job Board

This group is for posting jobs related to all aspects of the home performance industry including…See More
yesterday
Stacie Bagnasco replied to Evan Mills's discussion Dirty solar panels
"This is a great idea. I clicked on your discussion because it made me remember that I forgot to get…"
yesterday
Kirsten Richnavsky posted an event
Thumbnail

rCloud - The Future of Testing at Your Office or Home

October 18, 2017 from 2pm to 3pm
Integrating rCloud as an essential part of your RESNET QA process.Retrotec’s rCloud app is here,…See More
yesterday

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service