Comment by Gary Baggett on October 12, 2011 at 4:15pm
This job was one where I was just running audits for one of the states WAP agencies, so normally I'm just writing reports and work orders. This was basiclly a "911" call to the agency and it was repaired immediately while my guys went on to the next audit. I was going through some pictures today where I proctor in NYC and found all the ones from this house. I'll try to put them up later if I get the chance.
Comment by George Whiting on October 11, 2011 at 5:00pm
That would be some job to clean that boiler and flue.  Was there even a nozzle on the burner? LOL
Comment by Gary Baggett on October 11, 2011 at 4:08pm

George, it was an oil fired boiler that was only maybe 3 years old. Look at the Efficiency numbers. Did you see the photos of the exterior of the house? The owner "didn't realize there was a problem"...all the black soot above the unit on the ceiling didn't give anything away...nor the 4' circle it burned into the ground outside...

 

Comment by George Whiting on October 10, 2011 at 6:18pm
I've never seen numbers like that on CO!

Forum Discussions

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler 17 hours ago. 15 Replies

Psychrometric Chart Training

Started by John Krochmalny in Training. Last reply by Mahendra Shah 20 hours ago. 1 Reply

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco on Monday. 1 Reply

Latest Activity

tedkidd replied to Bob Blanchette's discussion Tankless Water Heaters... has their time finally come?
"Yeah. Gas water…"
10 hours ago
Eric Kjelshus replied to Bob Blanchette's discussion Tankless Water Heaters... has their time finally come?
"With super cheap natural gas prices now, still worth going all electric?  Tankless needs a lot…"
11 hours ago
Stuart Langley liked Chris Clay's photo
16 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"Stuart, I wasn't considering the copula windows... yes, those would indeed need to be…"
17 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"Well, @David Butler, you have seen the property more accurately than I have, but my impression of…"
17 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"@ Stuart,I don't think there's any concern about impact of 4" build-up on elevation…"
18 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"So this building has a few issues with air leaks and air leaks have so much to do with discomfort…"
19 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"John Hatfield has the right idea here for a new roof deck. Polyiso boards always need a good stout…"