Comment by Adam Zielinski on March 24, 2011 at 3:01pm

Sealing up a can light with a foam board box is a code violation and unsafe.  If you do it, you need to use a non combustible material, like drywall, or one of the tenmat mineral wood recessed light covers.  http://www.tenmat-us.com/

 

The Cree LR6 LED conversion kits are nice, and should cut down on air leakage.  However if you install them in a non-IC rated can light housing, you still are not supposed to put insulation over the top of them.  So you would still have to baffle around the can in the attic.   The best option for Non-IC can lights is to remove them and replace them with IC rated fixtures, or some other alternative lighting. 

 

Comment by Jim Gunshinan on January 24, 2011 at 5:42pm

Haven't heard of that Bob, thanks for the heads up!

 

Comment by Bob Small on January 20, 2011 at 6:04pm
Have you seen the Cree LR6 LED conversion? www.creeLLS.com Lets you switch to an LED bulb in a sealed unit that screws in to your existing can housing. Great price too.
Comment by Jim Gunshinan on December 20, 2010 at 1:55pm

Sorry, that was five years ago when Larry wrote his article.

Comment by Jim Gunshinan on December 20, 2010 at 1:54pm

Larry Armanda, who used to call himself the "Can Man" because he spent a lot of time looking at and fixing recessed can light leaks, wrote about it for Home Energy in 2005 "Further Wrestling with Recessed-Can Lights" (Sept/Oct). He didn't find a great retrofit kit, but Builders Best and Lithonia Lighting put out some good kits for sealing the can lights. That was ten years ago, so things may have changed.

 

At our house the contractors used a non-expanding spray foam to seal the lights where the fixture meets the ceiling. (The retrofit kits have a spongy gasket that does the same thing.) Then our contractor made boxes out of foam board to insulate the can-lights on the attic side. There was one problem—the can lights with incandescent lights stay on for about two hours and then the thermal cut off switch turns them off. The insulation makes the light fixture heat up rapidly inside. Without a thermal cutoff switch, the fire danger would be pretty serious. We put CFLs in the can-lights and fixed that problem. We need a brighter light in one room, over a desk, and still have an incandescent there. It cuts off after a few hours and I take it as a signal to get away from my desk for a while! They should be CFLs that give that kind of light but we haven't found it yet.

 

Hope this helps!

Comment by dale conner on December 20, 2010 at 10:36am

Do you know of a good kit for converting the leaky lights to sealed ones? I pulled my leaky lights out of my house and replaced them with sealed lights but only because I was able to access them via the attic space.

Forum Discussions

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler 4 hours ago. 15 Replies

Psychrometric Chart Training

Started by John Krochmalny in Training. Last reply by Mahendra Shah 7 hours ago. 1 Reply

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco on Monday. 1 Reply

Latest Activity

Stuart Langley liked Chris Clay's photo
3 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"Stuart, I wasn't considering the copula windows... yes, those would indeed need to be…"
4 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"Well, @David Butler, you have seen the property more accurately than I have, but my impression of…"
4 hours ago
David Butler replied to David Butler's discussion How would you insulate this roof?
"@ Stuart,I don't think there's any concern about impact of 4" build-up on elevation…"
5 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"So this building has a few issues with air leaks and air leaks have so much to do with discomfort…"
6 hours ago
Stuart Langley replied to David Butler's discussion How would you insulate this roof?
"John Hatfield has the right idea here for a new roof deck. Polyiso boards always need a good stout…"
6 hours ago
Keith Tripp replied to Sean Lintow Sr's discussion Water Saver or Gimmick? in the group Best Practices (Residential)
"Interesting to see that recirc. has been in use for many years in some places. It is still a…"
7 hours ago
Mahendra Shah replied to John Krochmalny's discussion Psychrometric Chart Training
"John Thanks for show and tell tutorial"
7 hours ago