Comment by Gary Baggett on February 7, 2011 at 9:05pm
Jack, I added some pics for you
Comment by Gary Baggett on February 7, 2011 at 8:53pm
lol...I didn't want to say that...I actually have a better picture of this somewhere. I should post a few on my "page"
Comment by Jack Baikoff on February 7, 2011 at 8:50pm
Yeah, thanks, sorry I did not notice it had an ambient CO display.
Comment by Gary Baggett on February 7, 2011 at 7:30pm
no, that was the co in the flu gases...which 400 constitutes an "emergency"
Comment by Jack Baikoff on February 7, 2011 at 7:25pm
OMG! What was the ambient CO reading?
Comment by Gary Baggett on February 7, 2011 at 3:44pm
Hey...I know where that picture came from...
Comment by Michael Dunseith on December 27, 2010 at 5:56pm
A friend of mind shared this with me the other day. I don't recommend keeping your very expense testing equipment in the flue any longer then need be.   Once you determined that the CO is excessive, does it really matter if its 500 ppm or more?  Note the efficiency!

Latest Activity

Dara Bowser replied to Don Fugler's discussion joining ducts in the group HVAC
"Good to hear you have clean dryer ducts Don. The dryer duct issues that we run into are…"
6 hours ago
Don Fugler replied to Don Fugler's discussion joining ducts in the group HVAC
"David, If the IMC mandates metal dryer duct and prohibits metal screws, they must be accepting…"
7 hours ago
David Butler replied to Don Fugler's discussion joining ducts in the group HVAC
"I never checked that before. Checking now... Section M1502.4.2 of the International Residential…"
7 hours ago
Joseph Frasier is now a member of Home Energy Pros Forum
7 hours ago
Don Fugler replied to Don Fugler's discussion joining ducts in the group HVAC
"Brendan, Thanks for that response. Because of your warning, I just went down to the basement and…"
11 hours ago
Brendan Reid replied to Don Fugler's discussion joining ducts in the group HVAC
"Hi Don, Summary: DRYER VENT: screws bad idea, possibly prohibited by code. METAL DUCT: must be…"
11 hours ago
Profile IconBrendan Reid and David Butler joined Allison A. Bailes III's group
Thumbnail

HVAC

HVAC design, Manuals J, S, T, & D, Duct leakage, Air flow, ENERGY STAR new home requirements,…See More
11 hours ago
Profile IconSean Wiens and David Butler joined Chris Laumer-Giddens's group
Thumbnail

Energy Efficient Design

Energy efficiency starts at the drafting table...How architects and designers can help buildings…See More
20 hours ago

Photos

  • Add Photos
  • View All

© 2017   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service