Foundation Thermal Sketch

This is here to point out the total lack of recognition of heat-transfer, we just patch up the problem with some insulation here, some vapor barrier there.

Views: 88

Comment

You need to be a member of Home Energy Pros Forum to add comments!

Join Home Energy Pros Forum

Comment by Tom Mallard on March 28, 2011 at 11:02am

The foundation is hard to control for heat-transfer due the compression loads, can't say I've solved anything other than to ponder insulation that can handle the loads to replace the board joists are usually nailed that's anchored to the concrete. That would be a worthy new product for energy conservation in home construction.

Another I've thought of tho' is where joists are open to the interior floor, that first foot needs to breathe but my opinion needs to be stuffed with insulation with the paper torn off to allow breathing of condensation but killing direct air movement.

That area is like a chiller in winter, the cold air from the wood gets warmed enough right there to rise and creep along the floor above the typical insulation just from sag between it and the wood!!

Comment by Tom Mallard on March 28, 2011 at 9:03am
Too true ... I'm such a misfit ...
Comment by Jim Peck on March 28, 2011 at 6:50am
As specie whom claims such intelligence, we do seem remarkably shortsighted

Forum Discussions

Speed Tips For Duct Airtightness Testing?

Started by Brendan Reid in General Forum. Last reply by David Butler 3 hours ago. 1 Reply

What made this chimney fall down?

Started by Eric Kjelshus in General Forum. Last reply by Eric Kjelshus on Tuesday. 7 Replies

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by Dave Taylor Nov 11. 61 Replies

Manual J (SD) for custom, luxury homes

Started by Dav Camras in HVAC. Last reply by Dav Camras Nov 10. 3 Replies

Quantitative methods for residential zoning

Started by Brett in HVAC. Last reply by David Butler Nov 9. 1 Reply

Latest Activity

Dara Bowser replied to Don Fugler's discussion joining ducts in the group HVAC
"Hi Don. We have never considered screws as impeding airflow, but I can see how in some ducts (e.g.…"
30 minutes ago
David Butler joined Chris Laumer-Giddens's group
Thumbnail

Energy Efficient Design

Energy efficiency starts at the drafting table...How architects and designers can help buildings…See More
2 hours ago
David Butler joined James White's group
Thumbnail

Building Simulations

Work collaboratively to find easier, more accurate and better ways to model, predict and verify a…See More
2 hours ago
David Butler joined Mark Richardson's group
Thumbnail

Renewable Energy

This group will focus on the issues associated with incorporating renewable energy sources like…See More
2 hours ago
David Butler joined Kyle Brown's group
Thumbnail

Wrightsoft - Manual J / Manual D

If you use Wrightsoft to calculate loads or design ducts, you likely have questions.  Get answers…See More
2 hours ago
Profile IconDavid Butler and Don Fugler joined Allison A. Bailes III's group
Thumbnail

HVAC

HVAC design, Manuals J, S, T, & D, Duct leakage, Air flow, ENERGY STAR new home requirements,…See More
2 hours ago
David Butler replied to Brendan Reid's discussion Speed Tips For Duct Airtightness Testing?
"The Home Performance Forum archives include a number of discussions on various methods for sealing…"
3 hours ago
Brendan Reid posted a discussion

Speed Tips For Duct Airtightness Testing?

Anyone like to share their favorite ways to speed up duct airtightness ("Ductblaster") tests?I'm…See More