Information

Tools of the Trade

A hammer and a saw used to be the key tools for home contractors. Today, the best-in-breed also use high-tech equipment while performing a professional energy audit or verifying that construction has been done correctly.

Members: 105
Latest Activity: Jul 21, 2017

Add Tools to the Tools of the Trade Page

Add tools to the Tools of the Trade page by starting a new discussion. Click + Start Discussion in the Discussion Forum below to post.

Discussion Forum

Seeking a Flow Hood

Started by George Matthews Apr 10, 2017. 0 Replies

Affordable Manometers?

Started by Isaac Savage. Last reply by Pete Stoermer Feb 15, 2016. 3 Replies

Looking For A Retrotech Duct Tester ?

Started by Chris Schiewer. Last reply by Jamie Kaye Dec 16, 2015. 1 Reply

Buying Used Equipment

Started by Nick Semon May 18, 2015. 0 Replies

Used Blower Doors?

Started by Isaac Savage. Last reply by Cameron Millard Jan 16, 2014. 3 Replies

Instant read thermometers

Started by Ryan Moore. Last reply by David Meiland Apr 29, 2013. 3 Replies

Good Place to Compare Appliances?

Started by Donna Sanders Jan 12, 2013. 0 Replies

Smoke puffers

Started by Paul Raymer. Last reply by Jim Gunshinan Mar 15, 2012. 8 Replies

CO Testing for BPI

Started by Paul Raymer. Last reply by Chris Stratton Mar 2, 2012. 6 Replies

Comment Wall

Comment

You need to be a member of Tools of the Trade to add comments!

Comment by A. Tamasin Sterner on February 10, 2011 at 10:33pm
Ladies and Gentlemen, I have to tell ya, I'm a HUGE fan of flexible probes!  Love my flexible probe for my Testo 327 - NO more drilling!! and, the flexible, lighted probe on my video boroscope is awesome!  Today, I saw what was happening under a dryer - solved a combustion air issue by cleaning!
Comment by Graeme Nix on December 28, 2010 at 5:03pm

Ron, Paul,

First, the flow rings are always attached on the inlet side of the fan, regardless of whether you pressurizing or depressurizing. Admittedly, this does make it less convenient to change the rings if that becomes needed, since you'll have to remove the flex duct first.

The ability to test in either direction, however, is a key feature of the Retrotec DucTester. It is true, Ron, that if the grill mask holds tight, there should be very little difference in the results between depressurization and pressurization, however, the possibility does exist that if it's not properly secured, the grill mask can be pushed off a register, leading to faulty results, or a repeated test. Hence our recommendation. However, it must be clearly said that if there's a risk of polluted, dusty, or mouldy air being pulled into the house, the ducts do not need to be depressurized.

Comment by A. Tamasin Sterner on December 24, 2010 at 2:39pm
We are using flexible probes for our combustion analyzers.  Great solution for checking undiluted flue gasses for CO content.  Instead of drilling holes in draft diverters in order to get the probe into the undiluted gasses, we use flexible probe.  Check out the photos I've uploaded.
Comment by Evan Mills on December 17, 2010 at 2:41am

Some discussion over here on choosing IR cameras and blower doors.

Comment by Ron Jones on December 12, 2010 at 9:02pm

Thanks for that.  I've been curios since you raised the topic if there would be a difference.  I'll try it some time with my Energy Conservatory Duct Blaster and if I see anything funny I'll let you know.

Comment by Paul Raymer on December 11, 2010 at 11:05am

Ron -  As far as running the Retrotec duct tester either way, after your question, I was teaching a class yesterday, and we ran the duct tester both ways and got exactly the same result.  It was extremely handy to be able to leave the blower door installed to quickly do the Total Pressure and then the Pressure to outside.  (The ducts in the building I was testing were awful to say the least.  Even the theatrical smoke was diluted to the extent that it was hard to see.)

Comment by Paul Raymer on December 11, 2010 at 11:02am

Tamasin -

I have been using a Motion Computing J3500 for auditing.  It's built for field work with "Gorilla" glass and a solid state drive.  It is not cheap, but it's incredibly fast and extremely bright even in direct sunlight.  It takes a little getting used to - carrying this amazing machine in an attic or crawl space.  It takes pictures and even can serve as a telephone.

I have been playing with HomeGauge software.  It is designed primarily for Home Inspectors, but it does have an energy template.  I am working with them to refine the output, but it has a spreadsheet for BPI combustion safety testing, etc.  I like the idea that it is on my computer and I don't have to pay annual fees or individual use fees or any other fees.  I haven't done it yet, but they can take your data on-line so that your clients can download it.  It's really easy to add pictures and they have an enormous bucket full of pre-written comments like warnings about windows not being the first step in saving energy.  It does figure area weighted R values and the BAS as well.

The first report I did was about 35 pages long, which is very fancy, but too much information for the average homeowner.

Comment by A. Tamasin Sterner on December 10, 2010 at 8:28pm

Is anyone using Tablets for auditing? If so, what are you using and what software?  Do you like it?

Comment by Ron Jones on December 8, 2010 at 9:33pm
I don't think Retrotec's argument holds much water. Have they tested a hundred house systems both ways, pressurized and then depressurized, and measured the difference? I can't imagine it would be enough to impact my recommendations to a homeowner. I'm not giving you a hard time, it's just that this is the first time I've heard depressurizing ducts suggested, so the possibilities are intriguing. Have you done it?
Comment by Paul Raymer on December 8, 2010 at 9:53am
That certainly may happen. Retrotec advises depressurizing so that the duct masks are pulled more tightly against the grilles rather than being pushed off. Also, if a "Leakage to Outside" test is going to be done using the blower door, the blower door fan doesn't have to be turned around to blow air into the house. And if it is a cold winter day, blowing 25 Pa of outside air into the house may be more detrimental than some leakage from the crawl space.
 

Members (104)

 
 
 

Discussion Forum

Seeking a Flow Hood

Started by George Matthews Apr 10, 2017. 0 Replies

Affordable Manometers?

Started by Isaac Savage. Last reply by Pete Stoermer Feb 15, 2016. 3 Replies

Looking For A Retrotech Duct Tester ?

Started by Chris Schiewer. Last reply by Jamie Kaye Dec 16, 2015. 1 Reply

Buying Used Equipment

Started by Nick Semon May 18, 2015. 0 Replies

Used Blower Doors?

Started by Isaac Savage. Last reply by Cameron Millard Jan 16, 2014. 3 Replies

Latest Activity

Brett Little posted an event
Thumbnail

Green Rater LEED Credential Online Training at Online

September 5, 2018 at 12pm to September 6, 2018 at 5pm
With over 450,000 LEED® for Homes™ spaces worldwide, LEED is the international rating system to…See More
1 hour ago
Michael Schettine commented on Michael Schettine's video
Thumbnail

AccuFrame Water Test

"The Like button doesn't work on this site..."
13 hours ago
Franco Oyuela commented on Mike Muras's blog post "Practical Standards to Measure HVAC System Performance" Rob "Doc" Falke 04/17/2006
"It's important to evaluate and inspect a system regularly to make sure it's at optimal…"
19 hours ago
Seventhwave posted an event

HVAC technology enhancements for energy conservation at The Marq

October 4, 2018 from 8:30am to 4pm
Join us to learn how to get the largest energy savings in your commercial buildings. HVAC as a…See More
23 hours ago
Peter Krych replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"I agree, it is wasteful to remove and dump old insulation. I still does its job. Air sealing is…"
yesterday
Michael Schettine commented on Michael Schettine's video
Thumbnail

AccuFrame Water Test

"With the conversion rate that- air is 800 time LESS dense than water at sea-level…"
yesterday
Michael Schettine posted a video

AccuFrame Water Test

In this short video, water is used to visualize air leakage sites that are present in the majority of framed walls in the US. New regulations require better ...
yesterday
Sam Feder liked Dav Camras's discussion Adding blown insulation to poorly installed batts?
yesterday
Chris Stratton liked Don Fugler's discussion Choosing a range hood
yesterday
Dave Taylor replied to Jerry Needham's discussion VERY TIGHT HOME WITH OVER SIZED AC
"Jerry, you should look at Buildingscience.com" High Mass Walls" 105 paper for more…"
yesterday
Jill Lindman's 3 events were featured
yesterday
Jill Lindman posted events
yesterday
Diane Chojnowski posted videos
yesterday
Don Fugler replied to Don Fugler's discussion Choosing a range hood in the group Kitchen Ventilation
"Has anyone installed a range hood in an older home with the ducting down to the basement and out…"
Thursday
Profile IconEileen Kraus-Dobratz, VENI MITTAL and Mark A McCrumb joined Home Energy Pros Forum
Thursday
Brian Robinson replied to Dav Camras's discussion Adding blown insulation to poorly installed batts?
"YES, YES, & YES!!! Bat droppings, mouse droppings, dead mice, nuts, seeds, acorns, lack of…"
Wednesday
Matt Peterson posted a blog post

The Importance of keeping Professionally Trained Gas Line Installation Technicians happy and loving their jobs!

Our company is very much a family to us, we strive to bring in and develop great people into great…See More
Wednesday
Profile Iconyanky fogel, Kathleen Krebs, Nicholas Rubenstein and 3 more joined Home Energy Pros Forum
Wednesday
yanky fogel liked Home Energy Magazine's video
Tuesday
Franco Oyuela commented on Shawn Weeks's blog post How Homeowners Can Keep Electricity Costs Down in Summer Months
"Cutting back on air conditioning is also good for the environment because it reduces carbon…"
Tuesday

Photos

  • Add Photos
  • View All

© 2018   Created by Home Performance Coalition (HPC)   Powered by