Event Description

TSFEE.com

Length: 4 hours

BPI CEU credits: 2

Description: Performing safety testing and deciding pass/fail is not enough these days. Customers want to know why their system has failed a test and what should be done to fix it. This class will teach the “how’s and why’s” of combustion safety testing and duct testing. The class is held at CEMA’s Heating lab in Cromwell, CT this allows hands on learning with many types of heating and cooling systems.

 

The class will discuss:

  • Proper testing procedures
  • Why common tests fail

  • What to recommend when a test fails.
  • When it is appropriate for a homeowner to address a issue versus when a professional is required
  • Identification heating/cooling systems by fuel/venting category, etc.
  • Spillage testing / Draft testing failure causes
  • Carbon Monoxide testing failure causes
  • Fuel type identification
  • Burner Type identification
  • Venting category Identification
  • Testing limitations under BPI and HES guidelines.
  • BTU rating of combustion appliances.

 

 

Prerequisite: This course is open to all students who have an interest and desire to learn how to perform energy audits and provide recommendations to the homeowner on improvements to improve the home’s energy performance. 

Comment Wall

Forum Discussions

Psychrometric Chart Training

Started by John Krochmalny in Training 7 hours ago. 0 Replies

Too many Heat Pump Water Heaters in a basement?

Started by Brad Cook in General Forum. Last reply by Michael Duclos 12 hours ago. 10 Replies

How would you insulate this roof?

Started by David Butler in General Forum. Last reply by David Butler on Monday. 2 Replies

Dirty solar panels

Started by Evan Mills in General Forum. Last reply by Stacie Bagnasco on Monday. 1 Reply

Latest Activity

B Eric Bell liked Bob Krell's group Healthy Indoors (IAQ)
4 hours ago
John Krochmalny posted a discussion

Psychrometric Chart Training

Looking through the various areas of this site, I didn't see too much information or training on…See More
7 hours ago
Profile IconMike Malek, Avery T. Phillips and Sarah Burger joined Home Energy Pros Forum
8 hours ago
Dannie Jackson's blog post was featured

Core Heat And Other Concepts

  In some places the use of solar heated liquids from hot water solar panels are used to provide…See More
12 hours ago
Michael Duclos replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"I’ve been looking into Sanden for a multi-family PH near Laconia, NH, ASHRAE 99.6% temp is…"
12 hours ago
Profile IconTroy Spindler, Mike Berg, Andrew McDowell and 4 more joined Home Energy Pros Forum
yesterday
David Butler replied to Brad Cook's discussion Too many Heat Pump Water Heaters in a basement?
"theoretically, let's say you perfectly isolate the HPWH from a heat source. The HPWH's…"
Monday
David Butler replied to David Butler's discussion How would you insulate this roof?
"Interesting idea. Commercial roof on a slope! Typical density for roofing spray foam is 2.5 to 3.0…"
Monday

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Home Performance Coalition (HPC)   Powered by

Badges  |  Report an Issue  |  Terms of Service